Multi-channel electronic circuit breaker for protecting four loads at 24 V DC in the event of overload or short circuit. With status output, reset input, and electronic locking of the set nominal currents. For installation on DIN rails. Multi-channel electronic equipment protection switch to protect four consumers in 24 V DC in case of overload and short circuit. With status output, reset input and electronic locking of the set rated currents. For installation on DIN rails.

Automation > Device circuit breaker
Over Current Protection

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1065727
Packing unit1 pc
Catalog pagePage 374 (C-4-2019)
GTIN4055626728780
Weight per Piece (excluding packing)140.000 g
Custom tariff number85363030
Country of originDE (Germany)

Drawings



Diagram

Diagram
Trigger characteristic in the DC range

Dimensional drawing

Dimensional drawing



Product drawing

Product drawing

Back to top

Dimensions

Height90 mm
Width36 mm
Depth98 mm (incl. DIN rail 7.5 mm)
Back to top

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Humidity test96 h, 95 % RH, 40 °C
Altitude≤ 3000 m up to 52 °C (amsl (above mean sea level))
≤ 4000 m up to 46 °C (amsl (above mean sea level))
Shock (operation)30g (IEC 60068-2-27, Test Ea)
Vibration (operation)10 Hz ... 57.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
57.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc)
Degree of protectionIP20
Back to top

General

Flammability rating according to UL 94V-0
Mounting typeDIN rail: 35 mm
Colorlight grey RAL 7035
Number of positions1
Protection classIII
TypeDIN rail module, one-piece
Back to top

Electrical data

Fuse typeelectronic
Rated surge voltage0.5 kV
Operating voltage18 V DC ... 30 V DC
Rated voltage24 V DC
Rated current INmax. 16 A DC (IN+)
max. 40 A DC (per terminal position when bridging additional devices via IN+)
1 / 2 / 3 / 4 A DC (adjustable per output channel)
Measuring tolerance I± 15 %
Feedback resistancemax. 35 V DC
Fail-safe element4 A DC (per output channel)
Efficiency> 99 %
Closed circuit current I0typ. 33 mA
Power dissipationtyp. 0.8 W (No-load operation)
< 4 W (Nominal operation)
Module initialization time1.6 s
Waiting time after switch off of a channel5 s (at overload / short circuit)
Tripping methodE (electronic)
Required backup fusenot required, integrated failsafe element
Dielectric strengthmax. 35 V DC (Load circuit)
MTBF (IEC 61709, SN 29500)11764705 h (at 25°C with 21% load)
5319148 h (at 40°C with 34.25% load)
846023 h (at 60°C with 100% load)
Shutdown time load circuit≤ 10 ms (for short circuit > 2.0 x IN)
1 s (1.2 ... 2.0 x IN)
Undervoltage shutdown load circuit≤ 17.8 V DC (active)
≥ 18.8 V DC (inactive)
Surge voltage shutdown load circuit≥ 30.5 V DC (active)
≤ 29.5 V DC (inactive)
Max. capacitive load load circuit30000 µF (Depending on the current setting and the short-circuit current available)
Output voltage status output24 V DC
Output current status outputmax. 0.04 A (Short-circuit-proof)
Stripping length10 mm
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Input voltage reset input7 V DC ... 30 V DC (Reset with falling edge)
Current consumption reset inputtyp. 0.4 mA (at 24 V DC)
Pulse length reset input≥ 50 ms (High)
≥ 50 ms (Low)
Voltage reset input< 5 V DC (Low state)
> 8 V DC (High state)
Stripping length10 mm
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Back to top

Signaling

Channel LED offoff (Channel switched off)
Channel LED greenlit (Channel switched on)
Channel LED yellowlit (Channel switched on, channel load > 80% )
flashing (Programming mode active)
Channel LED redlit (Channel switched off, over- or undervoltage active)
ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release)
flashing (Channel switched off, ready to be switched back on, overload or short-circuit release)
two flashes (Channel switched off, device total current limit 40 A exceeded)
Back to top

Connection data

Connection nameMain circuit IN+
Connection methodPush-in connection
Stripping length15 mm
Conductor cross section solid0.2 mm² ... 10 mm²
Conductor cross section AWG24 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 6 mm²
Connection nameMain circuit IN-
Connection methodPush-in connection
Stripping length10 mm
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Connection nameMain circuit OUT+
Connection methodPush-in connection
Stripping length10 mm
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Back to top

Standards and Regulations

Standards/specificationsEN 61000-6-2
EN 61000-6-3
EN 60068-2-6
EN 60068-2-27
EN 60068-2-78
EN 50178
Back to top

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 10.0.127140401
eCl@ss 4.027141100
eCl@ss 4.127141100
eCl@ss 5.027141100
eCl@ss 5.127141100
eCl@ss 6.027141100
eCl@ss 7.027141116
eCl@ss 8.027141116
eCl@ss 9.027141116
Back to top

ETIM

ETIM 5.0EC000899
ETIM 6.0EC000899
ETIM 7.0EC000899
Back to top

UNSPSC

UNSPSC 13.239121410
UNSPSC 18.039121410
UNSPSC 19.039121410
UNSPSC 20.039121410
UNSPSC 21.039121410
Back to top

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.