PHOENIX CONTACT CB E1 24DC/8A NO P CB E1 24DC/8A NO P 2800906 PHOENIX CONTACT Electronic device circuit breaker View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CB E1 24DC/8A NO P 2800906 PHOENIX CONTACT Electronic device circuit breaker

CB E1 24DC/8A NO P

2800906

PHOENIX CONTACT

1 Pcs.

Electronic device circuit breaker Interruption. Protec. Electronic, 1 pole, active current limiter, 1 NO contact, connector for base element. Electronic circuit breaker, 1-pole, active current limiter, 1 normally open contact, plug for base element.

Automation > Device circuit breaker
Over Current Protection

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2800906
Packing unit1 pc
GTIN4046356690768
Weight per Piece (excluding packing)36.400 g
Custom tariff number85362010
Country of originDE (Germany)

Dimensions

Height45 mm
Width12.3 mm
Depth52 mm
Complete module height90 mm
Complete module width12.3 mm
Complete module depth77.3 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 50 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Humidity test96 h, 95% RH, 40°C
Vibration (operation)3g (In accordance with IEC 60068-2-6, Test Fc)
Degree of protectionIP30 (Actuation area)

General

Flammability rating according to UL 94V0
Mounting typeon base element
Colorgray
Number of positions1
Degree of pollution2
TypeMale

Electrical data

Fuse typeelectronic
Rated surge voltage0.5 kV
Operating voltage24 V DC
18 V DC ... 30 V DC
Nominal current IN8 A
Active current limitationtyp. 1.25 x IN
Closed circuit current I0typ. 8 mA (When switched on)
typ. 17 mA (With alarm output)
Power dissipation1.21 W (Nominal operation)
Temperature derating7.2 A (at 50 °C)
Tripping methodE (electronic)
Required backup fusenot required, integrated failsafe element
Dielectric strengthmax. 30 V DC (Load circuit)
Voltage drop100 mV (at IN)
Shutdown time load circuit100 ms (see time/current characteristic curve)
Undervoltage shutdown load circuit< 14 V (typ. OFF)
> 17 V (typ. ON)
Max. capacitive load load circuit20000 µF
Auxiliary type of contactfloating signal contact
Minimum auxiliary contact operating voltage10 V DC
Maximum auxiliary contact operating voltage30 V DC
Minimum auxiliary contact operating current10 mA
Maximum auxiliary contact operating current0.5 A

Standards and Regulations

Standards/specificationsUL 2367 UL recognized
UL 508 UL/C-UL listed
EMV EN 61000-6-3 Interference emission
EMV EN 61000-6-2 Noise immunity

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2800906 Circuit breakers and fuses (EC003538)
Feature Name Feature Value
Inflammability class of insulation material according to UL94 (EF002521) Other
Number of poles (EF001391) 1
Construction type (EF000767) Plug
Width (EF000008) 12.3 mm
Height (EF000040) 45 mm
Depth (EF000049) 52 mm
Mounting method (EF000003) Other
Operating voltage (EF000111) 30 V
Nominal current (EF000001) 8 A
Active current limitation x IN (EF011922) 1.25
Fuse type (EF011923) Electronic
Fail safe element (EF011924) 15 A
Switch-off time (EF011925) 0.1 ms
Max. capacitive load (EF011926) 0.02 µF
With remote signalling contact (EF000422) No
Ambient temperature during operating (EF007515) -25 °C

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.