PHOENIX CONTACT CAPAROC PM S-R EX CAPAROC PM S-R EX 1344363 PHOENIX CONTACT Power module with status output and reset input for the power supp.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CAPAROC PM S-R EX 1344363 PHOENIX CONTACT Power module with status output and reset input for the power supp..

CAPAROC PM S-R EX

1344363

PHOENIX CONTACT

1 Pcs.

Power module with status output and reset input for the power supply of the switch system for protection of CAPAROC equipment with 12 or 24 V DC. EX e approval for zone 2. To be installed on DIN rails using CAPAROC busbars. Power module Power module with status output and reset input for supplying the CAPAROC circuit breaker system with 12 V DC or 24 V DC. EX e approval for zone 2. For DIN rail installation via the CAPAROC current rails.

Automation > Device circuit breaker
Over Current Protection

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
General
NoteLABS release – in accordance with test specification VW PV 3.10.7:2005-0
When connecting the conductor, make sure that the CAPAROC modules are not pulled apart due to tensile force. Gaps must not be created between the modules.
Observe the specified conditions for use in potentially explosive areas. Install the device in a suitable approved housing with at least IP54 degree of protection that meets the requirements of IEC/EN 60079-0. Also observe the requirements of IEC/EN 60079-14.

Product properties
TypePlug-in module
Product typeDevice circuit breakers
Product familyCAPAROC
Number of slots2
Insulation characteristics
Protection classIII
Pollution degree2

Electrical properties
General
Operating voltage10 V DC ... 30 V DC
Rated voltage12 V DC
24 V DC
Rated current IN45 A DC (Total current input)
Rated surge voltage0.5 kV
Tripping methodE (electronic)
Dielectric strength35 V DC (Load circuit)
Efficiency> 99 %
Closed circuit current I0typ. 9 mA (no load at 24 V)
Power dissipationtyp. 0.22 W (no load at 24 V)
< 1.5 W (in nominal operation at 24 V and 45 A)
Temperature derating45 A (Total current at 40°C)
30 A (Total current at 65 °C)
MTBF (IEC 61709, SN 29500)18886912.65 h (at 25 °C with 21 % load)
5907048.64 h (at 40°C with 34.25% load)
933563.97 h (at 40°C with 100% load)
Voltage drop0.03 V (at 45 A)
Reset
Input voltage range7 V DC ... 30 V DC (Reset with falling edge)
Current consumptiontyp. 0.5 mA (at 24 V DC)
Pulse length≥ 50 ms
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve0.2 mm² ... 0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.2 mm² ... 1.5 mm²
Status output
Output voltagemax. 30 V DC (Input voltage ±5% in the event of no error)
0 V DC (Error)
Output currentmax. 20 mA
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve0.2 mm² ... 0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.2 mm² ... 1.5 mm²
Status output
Output voltagemax. 30 V DC (Input voltage ±5% when I >80% at at least one channel)
Output currentmax. 20 mA
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve0.2 mm² ... 0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.2 mm² ... 1.5 mm²

Connection data
Cross section AWG(converted acc. to IEC)
Main circuit IN+
Connection methodPush-in connection
Stripping length18 mm
Conductor cross section rigid0.5 mm² ... 16 mm²
Conductor cross section AWG20 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve0.5 mm² ... 16 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.5 mm² ... 16 mm²
Main circuit IN-
Connection methodPush-in connection
Stripping length18 mm
Conductor cross section rigid0.5 mm² ... 16 mm²
Conductor cross section AWG20 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve0.5 mm² ... 16 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.5 mm² ... 16 mm²

Signaling
Power (PWR) LED greenlit (with no channel errors)
lit (Supply voltage in the nominal range)
flashing (3 x on deactivation of programming lock)
Power (PWR) LED redlit (Supply voltage outside the nominal range)

Dimensions
Dimensional drawingzytudyzccq.jpg
Width12.4 mm
Height132.4 mm
Depth111.3 mm (incl. DIN rail 7.5 mm)

Material specifications
MaterialPA 6
PA 6
PA 6
PC
Flammability rating according to UL 94V-0

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-30 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Altitude≤ 4000 m (amsl)
Humidity test96 h, 95 % RH, 40 °C
Shock (operation)30g (11 ms period, half-sine shock pulse, according to IEC 60068-2-27)
25g (6 ms duration, half-sine shock pulse in accordance with IEC 60068-2-27, continuous shock)
Vibration (operation)5g (10 ... 150 Hz / 10 cycles / axis / X, Y, Z)

Approvals
UL approval
IdentificationUL/C-UL Listed UL 508
UL 121201 Class I, Division 2, Groups A, B, C, D, T4A
ATEX
IdentificationTÜV 22 ATEX 8874 X
II 3G Ex ec IIC T4 Gc
IECEx
IdentificationIECEx TUR 22.0049X
II 3G Ex ec IIC T4 Gc
UKCA Ex (UKEX)
IdentificationTÜV 22 UKEX 7109 X
II 3G Ex ec IIC T4 Gc

Standards and regulations
Standards/specificationsEN 61000-6-2
NoteEMC – Immunity for industrial areas
Standards/specificationsEN 61000-6-3
NoteEMC – Emission for residential, business and commercial properties and small operations
Standards/specificationsEN 60068-2-78
NoteEnvironmental influences – Moisture and heat, constant
Standards/specificationsEN 50178
NoteEquipping power installations with electronic equipment
Standards/specificationsEN 60068-2-27
NoteEnvironmental influences – Shocks
Standards/specificationsIEC 60079-7
NoteExplosive atmospheres – Part 7: Equipment protection by increased safety “e”
Standards/specificationsIEC 60079-0
NoteExplosive atmospheres – Part 0: Equipment – General requirements

Mounting
Mounting typepluggable onto CAPAROC CR… current rail

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.