View larger
SAC-5P-100,0-PVC/SH-0,34
1550672
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product type | Cable by the meter |
| Application | Connector |
| Number of positions | 5 |
| Shielded | yes |
| Cable length | 100 m |
| PVC black [PVC] | |
| Dimensional drawing | ![]() |
| Cable weight | 55 kg/km |
| Number of positions | 5 |
| Shielded | yes |
| Cable type | PVC black [PVC] |
| Conductor structure signal line | 42x 0.10 mm |
| AWG signal line | 22 |
| Conductor cross section | 5x 0.34 mm² (Signal line) |
| Wire diameter incl. insulation | 1.35 mm ±0.02 mm |
| External cable diameter | 5.90 mm ±0.2 mm |
| Outer sheath, material | PVC |
| External sheath, color | black RAL 9005 |
| Conductor material | Bare Cu litz wires |
| Material, filler | PVC |
| Material wire insulation | PVC |
| Single wire, color | brown, white, blue, black, gray |
| Thickness, insulation | ≥ 0.23 mm (Core insulation) |
| ≥ 0.76 mm (Outer cable sheath) | |
| Overall twist | 5 wires around filler to the core |
| Optical shield covering | 85 % |
| Max. conductor resistance | ≤ 58 Ω/km (at 20 °C) |
| Insulation resistance | ≥ 10 MΩ*km (at 20 °C) |
| Nominal voltage, cable | ≤ 300 V |
| Test voltage | ≥ 3000 V |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, fixed installation | 30 mm |
| Smallest bending radius, movable installation | 59 mm |
| Flame resistance | As per UL-Style 2464 |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Ambient temperature (operation) | -25 °C ... 80 °C (cable, fixed installation) |
| -5 °C ... 80 °C (Cable, flexible installation) | |
| Feature Name | Feature Value |
|---|---|
| Conductor surface (EF010804) | Other |
| Diameter conductor (EF001621) | 1.35 mm |
| Nominal cross section conductor (EF000060) | 0.34 mm² |
| Conductor category (EF001632) | Class 6 = very flexible |
| Number of cores (EF001792) | 5 |
| Material core insulation (EF000061) | Polyvinyl chloride (PVC) |
| Specification core insulation (EF011805) | Other |
| Core identification (EF000067) | Other |
| Screen over stranding element (EF001623) | Braiding |
| Longitudinal water blocking cable (EF011011) | No |
| Radial water blocking cable (EF011012) | No |
| Suitable for underground installation (EF003689) | No |
| Protective sheath (EF001691) | None |
| Material outer sheath (EF001625) | Polyvinyl chloride (PVC) |
| Specification material outer sheath (EF011806) | Other |
| Colour outer sheath (EF001618) | Other |
| Low smoke according to EN IEC 61034-2 (EF003799) | No |
| Oil resistant according to EN IEC 60811-404 (EF009770) | No |
| Outer diameter approx. (EF003921) | 5.9 mm |
| Min. permitted bending radius, moving application/free movement (EF011802) | 59 mm |
| Min. permitted bending radius, stationary application/permanent installation (EF011803) | 30 mm |
| Permitted cable outer temperature during assembling/handling (EF001685) | -5 °C |
| Permitted cable outer temperature after assembling without vibration (EF001686) | -25 °C |
| Category (EF001619) | Other |