PHOENIX CONTACT BC 107,6 OT 1120 KMGY BC 107,6 OT 1120 KMGY 1554865 PHOENIX CONTACT Rail enclosure for use in installation distributors according .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

BC 107,6 OT 1120 KMGY 1554865 PHOENIX CONTACT Rail enclosure for use in installation distributors according ..

BC 107,6 OT 1120 KMGY

1554865

PHOENIX CONTACT

500 Pcs.

Rail enclosure for use in installation distributors according to DIN 43880, Modular housing top, width: 107.6 mm, height: 89.7 mm, depth: 54.85 mm, colour: light grey (Similar to RAL 7035)

Automation > Extruded profile modular housing
Housing (HS)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
GeneralLook at the series datasheet in the download area.

Item Properties
Product TypeTop of the case
Max. number of poles64 (pitch: 2.5 mm)
48 (pitch: 3.5 mm)
40 (pitch: 5 mm)
24 (pitch: 7.5 mm)
ExecutionModular Housing Top
Type of housingRail housing for use in installation distributors in accordance with DIN 43880
Available ventilation holeYes
Housing SeriesBC

Connection data
AWG Conductor Section(Converted according to IEC)

Dimensions
Dimension Schemejelfbrhpcj.jpg
Width107.6 mm
Height89.7 mm
Depth54.85 mm
Split Unit6 pcs
Printed circuit board design
Printed Circuit Board Thickness1.4 mm ... 1.8 mm

Material Data
ColourLuminous Grey (7035)
Flammability class according to UL 94V0
Surface CharacteristicsNot Treated
Shell materialPolycarbonate

Environmental and life-life conditions
Vibration test
Test SpecificationDIN EN 60068-2-6 (VDE 0468-2-6):2008-10
frequency10 - 150 - 10 Hz
Sweep speed1 octave/min
Amplitude0.15 mm (10 Hz ... 58.1 Hz)
Acceleration2g (58.1 Hz ... 150 Hz)
Test duration per axis2.5 h
Test DirectionsX, Y, and Z axes
Essay filam. incandescent
Test SpecificationDIN EN 60695-2-11 (VDE 0471-2-11):2014-11
Temperature850 °C
Performance Time30 sec
Mechanical Strength/Descending Drum
Test SpecificationDIN EN 60068-2-31 (VDE 0468-2-31):2009-04
Drop Height50 cm
frequency50
Crash
Test SpecificationDIN EN 60068-2-27 (VDE 0468-2-27):2010-02
Shock TypeSemi-sinusoid
Acceleration35%
Duration of the crash11 ms
Number of collisions per steering3
Test DirectionsX, Y, and Z axes (pos. and neg.)
Protection rating (IP code)
Test SpecificationDIN EN 60529 (VDE 0470-1):2014-09
Environmental conditions
Maximum achievable IP codeIP20
Ambient Temperature (Service)-40 °C ... 105 °C (depending on dissipation)
Ambient Temperature (Storage/Transport)-40 °C ... 70 °C
Ambient Temperature (Mounting)-5 °C ... 100 °C
Relative humidity of the air (storage/transport)95 %

Printed Circuit Board Data
Number of PCB Housings12
Printed Circuit Board Attachment TypeBlockade
Printed Circuit Board Thickness1.4 mm ... 1.8 mm

assembly
Type of mountingFit
Position for mountingVertical (horizontal rail)

Packaging Information
Type of packagingBoxed Packaging
Outer packing typeCardboard

ETIM for 1554865 Low-voltage industrial controls and switchgear (EC002779)
Feature Name Feature Value
Type of enclosure (EF003086) Closed
Housing connectable (EF003088) No
Suitable for rail mounting (EF003972) No
Wall mounting possible (EF003973) No
With integrated PCB-mounting connection system (EF003087) No
Material (EF002169) Other
Surface finishing (EF006569) Other
Colour (EF000007) Grey
RAL-number (EF000116) 7035
Width (EF000008) 107.6 mm
Height (EF000040) 89.7 mm
Depth (EF000049) 54.85 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.