View larger
AXL F UTH4 1H
2688598
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2688598 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 119 (C-6-2017) |
| GTIN | 4046356780117 |
| Weight per Piece (excluding packing) | 144.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
| Dimensional drawing | |
|---|---|
| Width | 35 mm |
| Height | 126.1 mm |
| Depth | 54 mm |
| Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
| Designation | Axioline F connector |
|---|---|
| Connection method | Push-in connection |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
| Mounting type | DIN rail |
|---|---|
| Net weight | 144 g |
| Note on weight specifications | with connectors and bus base module |
| Designation | Axioline F local bus |
|---|---|
| No. of channels | 2 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| Designation | Axioline F local bus supply (UBus) |
|---|---|
| Supply voltage | 5 V DC (via bus base module) |
| Current consumption | typ. 112 mA |
| max. 160 mA | |
| Power consumption | typ. 0.54 W (logic) |
| max. 0.8 W (logic) | |
| Designation | Supply for analog modules (UA) |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 23 mA |
| max. 40 mA | |
| Power consumption | max. 0.96 W (Peripherals) |
| typ. 1.05 W (entire device) | |
| max. 1.76 W (entire device) | |
| Type of protection | Surge protection of the supply voltage |
| Polarity reversal protection of the supply voltage | |
| Transient protection |
| Number of inputs | 4 +1 (4 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V) |
|---|---|
| Input name | Analog inputs |
| Description of the input | Inputs for thermocouples or linear voltage |
| Connection method | Spring-cage connection with direct connector-in method |
| Connection technology | 2-wire (shielded, twisted pair) |
| Sensor types (RTD) that can be used | Pt 100 (2 external cold junctions, can also be used as a sensor input) |
| Measuring principle | Sigma/Delta process |
| Measured value representation | 16 bits (15 bits + sign bit) |
| Resolution A/D | 24 bit |
| Type of protection | Short-circuit protection, overload protection of the inputs |
| Transient protection of inputs | |
| Input filter time | 40 ms |
| Test section | 5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min. |
|---|---|
| 5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min. | |
| 24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min. |
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |