PHOENIX CONTACT AXL F AO4 XC 1H AXL F AO4 XC 1H 2702153 PHOENIX CONTACT I/O module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AXL F AO4 XC 1H 2702153 PHOENIX CONTACT I/O module

AXL F AO4 XC 1H

2702153

PHOENIX CONTACT

1 Pcs.

I/O module AxiolineF, Analog Output Module, Analog Outputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA... 20 mA, 4 mA... 20 mA, connection technology: 2 conductors, transmission rate on local bus: 100 MBit/s, Extreme Conditions variant, protection rating: IP20, including bus socket module and AxiolineF connectors Axioline F, Analog output module, Analog outputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20, including bus base module and Axioline F connectors

Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Dimensions
Dimensional drawingipszsistrh.jpg
Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Notes
Note on application
Note on applicationOnly for industrial use

Interfaces
Axioline F local bus
Number of interfaces2
Connection methodBus base module
Transmission speed100 Mbps

System properties
Module
Input address area8 Byte
Output address area8 Byte
Required parameter data14 Byte
Required configuration data7 Byte

Output data
Analog:
Output nameAnalog outputs
Connection methodPush-in connection
Connection technology2-conductor
Note regarding the connection technologyshielded, twisted pair
Number of outputs4
D/A converter resolution16 bit
Protective circuitShort-circuit and overload protection; electronic
Transient protection; Suppressor diode
Data formatsIB IL, S7-compatible
Representation of output values16 bits (15 bits + sign)
Process data update140 µs
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
Load/output load current output≤ 500 Ω
Voltage output signal0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Load/output load voltage output≥ 1 kΩ

Product properties
Product typeI/O component
Product familyAxioline F
Typeblock modular
Mounting positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors
Special propertiesExtreme conditions version
Data management status
Article revision07
Insulation characteristics
Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties
Maximum power dissipation for nominal condition3.4 W
Potentials: Axioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current drawmax. 150 mA
typ. 120 mA
Potentials: Supply for analog modules (UA)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 125 mA (4 current channels, 24 mA output, 500 Ω load)
typ. 60 mA (4 voltage channels, 10 V output)
max. 85 mA (4 voltage channels, 10 V output)
max. 110 mA (4 current channels, 20 mA output, 500 Ω load)
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; Polarity protection diode
Transient protection; Suppressor diode
Electrical isolation/isolation of the voltage ranges
Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus)/analog outputs500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O)/analog outputs500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: Analog outputs/functional ground500 V AC, 50 Hz, 1 min.

Connection data
Connection technology
Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor connection
Connection methodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm
Axioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of protectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and regulations
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Approvals
ATEX
Identification II 3 G Ex ec IIC T4 Gc
CertificateUL 20 ATEX 2441X
References to standardsEN IEC 60079-0, EN IEC 60079-7
UKEX
Identification II 3 G Ex ec IIC T4 Gc
CertificatePxCIMA22UKEX2701949X
References to standardsEN IEC 60079-0, EN IEC 60079-7
IECEx
IdentificationEx ec IIC T4 Gc
CertificateIECEx ULD 20.0026X
References to standardsIEC 60079-0 Ed. 7, IEC 60079-7 Ed. 5.1
UL, USA/Canada
IdentificationcULus
CertificateE238705
UL Ex, USA / Canada
IdentificationClass I, Zone 2, AEx ec IIC T4
Class I, Division 2, Groups A, B, C, D, T4
Ex ec IIC T4 Gc X
CertificateE366272
References to standardsUL 60079-0 Ed. 7 / CSA C22.2 NO. 60079-0 Ed. 4
UL 60079-7 Ed. 5 / CSA C22.2 NO. 60079-7 Ed. 2
CCC / China-Ex
IdentificationEx ec IIC T4 Gc
Certificate, 2021122309114456
References to standardsGB/T 3836.1-2021, GB/T 3836.3-2021

Mounting
Mounting typeDIN rail mounting
Mounting positionany (no temperature derating)

ETIM for 2702153 PLC's (EC001596)
Feature Name Feature Value
Supply voltage DC (EF007534) 19.2 V
Voltage type (supply voltage) (EF002991) DC
Input, current (EF003204) No
Input, voltage (EF003205) No
Input, resistor (EF003206) No
Input, resistance thermometer (EF003207) No
Input, thermocouple (EF003208) No
Input signal, configurable (EF003209) No
Output, current (EF003212) Yes
Output, voltage (EF003213) Yes
Output signal configurable (EF003214) Yes
Resolution of the analogue outputs (EF003577) 16 Bit
Number of analogue inputs (EF001994) 0
Number of analogue outputs (EF001995) 4
Analogue inputs configurable (EF008518) No
Analogue outputs configurable (EF008519) Yes
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
Supporting protocol for EtherCAT (EF017564) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) Yes
Radio standard Bluetooth (EF007178) No
Radio standard WLAN 802.11 (EF007179) No
Radio standard GPRS (EF008523) No
Radio standard GSM (EF008524) No
Radio standard UMTS (EF008525) No
IO link master (EF007298) No
System accessory (EF004118) Yes
Degree of protection (IP) (EF005474) IP20
Type of electric connection (EF003961) Other
Fieldbus connection over separate bus coupler possible (EF004002) Yes
Suitable for rail mounting (EF003972) Yes
Wall mounting/direct mounting (EF007020) Yes
Front built-in possible (EF007016) No
Rack-assembly possible (EF007018) No
Suitable for safety functions (EF001597) No
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Width (EF000008) 35 mm
Height (EF000040) 125.893334 mm
Depth (EF000049) 52.649984 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.