View larger
AXL E PB IOL8 DI4 M12 6P
2701503
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2701503 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 203 (C-6-2017) |
| GTIN | 4046356763554 |
| Weight per Piece (excluding packing) | 552.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
| Dimensional drawing | |
|---|---|
| Width | 60 mm |
| Height | 185 mm |
| Depth | 30.5 mm |
| Note on dimensions | The height is 212 mm including fixing clips. |
| Drill hole spacing | 198.5 mm |
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % |
| Permissible humidity (storage/transport) | 5 % ... 95 % |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP65/IP67 |
| Designation | PROFIBUS DP |
|---|---|
| No. of channels | 2 |
| Connection method | M12 fast connection technology |
| Note on the connection method | B-coded |
| Designation connection point | Copper cable |
| Transmission speed | 9.6 kbps ... 12 Mbps (Automatic baud rate detection) |
| Transmission physics | PROFIBUS-DP-compliant copper cable |
| Address area assignment | 1 ... 126, adjustable |
| Number of positions | 5 |
| Designation | PROFIBUS DP |
|---|---|
| Equipment type | PROFIBUS slave |
| System-specific protocols | PROFIBUS protocols DP V1 |
| Designation | Module electronics and sensors (US) |
|---|---|
| Connection method | M12 connector (T-coded) |
| Number of positions | 4 |
| Supply voltage | 24 V DC |
| Nominal supply voltage range | 19.5 V DC ... 31.2 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 170 mA ±15 % (at 24 V DC) |
| Designation | Actuators (UA) |
| Connection method | M12 connector (T-coded) |
| Number of positions | 4 |
| Supply voltage | 24 V DC |
| Nominal supply voltage range | 18 V DC ... 31.2 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 30 mA ±15 % (at 24 V DC) |
| Nominal voltage for I/O supply | 24 V DC |
|---|---|
| Nominal current for every IO-Link port | max. 150 mA (at C/Q (pin 4), maximum of 1.6 A over all 8 IO-Link C/Q and L+ cables) |
| max. 200 mA (at L+/L- (pin 1 and pin 3), during startup, up to 1.6 A for short periods) | |
| max. 2 A (at UA(IO-Link B ports, pin 2 and pin 5)) | |
| Type of protection | Overload protection |
| Permissible cable length | < 20 m |
| Input name | Digital inputs at pin 2 for type A ports |
|---|---|
| Description of the input | IEC 61131-2 type 1 |
| Connection method | M12 connector, X01 ... X04 have double occupancy |
| Connection technology | 3-wire |
| Number of inputs | 4 |
| Type of protection | Overload protection, short-circuit protection of sensor supply |
| Input filter time | < 1000 µs |
| Input voltage range "0" signal | -0.3 V DC ... 5 V DC |
| Input voltage range "1" signal | 15 V DC ... 30 V DC |
| Input frequency | 0.5 kHz |
| Nominal input current at UIN | typ. 3 mA |
| Description of the input | IO-Link ports in digital input (DI) mode |
| Connection method | M12 connector, X01 ... X04 have double occupancy |
| Connection technology | 3-wire |
| Number of inputs | max. 8 (EN 61131-2 type 1) |
| Nominal input voltage UIN | 24 V DC |
| Input voltage range "0" signal | -0.3 V DC ... 5 V DC |
| Input voltage range "1" signal | 15 V DC ... 30 V DC |
| Nominal input current | typ. 3 mA |
| Sensor current per channel | max. 200 mA (from L+/L-) |
| Total sensor current | max. 1.6 A (from L+/L-) |
| Input filter time | < 1000 µs |
| Input frequency | 0.5 kHz |
| Type of protection | Overload protection |
| Short-circuit protection for the sensor supply |
| Number of ports | 4 |
|---|---|
| Connection method | M12 fast connection technology |
| Connection technology | 3-wire |
| Port type | Class A |
| Output description | IO-Link ports in digital output (DO) mode |
|---|---|
| Connection method | M12 connector, X01 ... X04 have double occupancy |
| Connection technology | 3-wire |
| Number of outputs | max. 8 |
| Nominal output voltage | 24 V DC |
| Maximum output current per channel | 150 mA |
| Maximum output current per device | 1.2 A |
| Nominal load, ohmic | 3.6 W (160 Ω, at nominal load) |
| Nominal load, inductive | 3.6 VA (0.8 H, 160 Ω, at nominal load) |
| Signal delay | max. 150 µs (when switched on) |
| max. 200 µs (when switched off) | |
| Switching rate | 1 per second, maximum (at nominal inductive load) |
| Limitation of the voltage induced on circuit interruption | -15 V DC |
| Output voltage when switched off | max. 1 V |
| Output current when switched off | max. 300 µA |
| Type of protection | Overload protection |
| Short-circuit protection | |
| Behavior with overload | Shutdown with automatic restart |
| Test section | 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection 500 V AC 50 Hz 1 min. |
|---|---|
| 24 V supply (communications power and sensor supply, IO-Link ports)/FE 500 V AC 50 Hz 1 min. | |
| Bus connection / FE 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, IO-Link ports) 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/bus connection 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/FE 500 V AC 50 Hz 1 min. |
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
| China RoHS | Environmentally Friendly Use Period = 25; |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |