View larger
AXC 1050
2700988
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2700988 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 76 (C-6-2017) |
| GTIN | 4046356731195 |
| Weight per Piece (excluding packing) | 225.600 g |
| Custom tariff number | 85371091 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (according to DIN EN 61131-2) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
| Shock | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
| Vibration (operation) | 5g |
| Engineering tool | PC WORX |
|---|---|
| PC WORX EXPRESS | |
| Programming languages supported | Programming in acc. with IEC 61131-3 |
| Diagnostics tool | DIAG+ |
| Configuration tool | Config+ Version 1.01 or later |
| Engineering tool | PC WORX |
|---|---|
| PC WORX EXPRESS | |
| Program memory | 2 Mbyte |
| Mass storage | 2 Mbyte |
| Retentive mass storage | 48 kByte (NVRAM) |
| Number of control tasks | 8 |
| Realtime clock | Yes |
| Amount of process data | max. 4096 Bit (Axioline F local bus (input)) |
|---|---|
| max. 4096 Bit (Axioline F local bus (output)) | |
| max. 32768 Bit (internal Modbus /TCP client) | |
| Number of supported devices | max. 63 (per station) |
| Number of local bus devices that can be connected | max. 63 (observe current consumption) |
| Interface | Axioline F local bus |
|---|---|
| Number | 1 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| Interface | Ethernet |
| Number | 2 |
| Connection method | RJ45 socket |
| Transmission speed | 10/100 Mbps |
| Interface | Service |
| Number | 1 |
| Connection method | Micro USB type B |
| Transmission speed | max. 115.2 kbps |
| Device function | PROFINET controller, PROFINET device |
|---|---|
| Specification | Version 2.2 |
| Update rate | min. 32 ms (16 devices) |
| min. 32 ms (8 devices) | |
| min. 16 ms (4 devices) | |
| min. 8 ms (2 devices) | |
| min. 4 ms (1st device) |
| Typical current consumption | 125 mA |
|---|---|
| Max. current consumption | 160 mA |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Residual ripple | ± 5 % |
| Power dissipation | max. 3 W |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Interference emission | Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B |
| Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV |
| Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV |
| Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
| Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
| Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V |
| Vibration (storage/transport) | 5g |
| Shock | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
| Vibration (operation) | 5g |
| Shock (operation) | 10g (Bump endurance test according to DIN EN 60068-2-27) |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |