Inline terminal Inline, Analog Input Module, Analog Inputs: 4, 0 V ... 10 V, -10 V ... 10 V, connection technology: 2 conductors, transmission rate on the local bus: 500 kBit/s, protection rating: IP20, including inline connector and marking surface

Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2700459
Packing unit1 pc
Catalog pagePage 159 (C-6-2017)
GTIN4046356566537
Weight per Piece (excluding packing)88.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Dimensional drawing
Width12.2 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight88 g
Note on weight specificationswith connector
Diagnostics messagesFailure of the internal I/O supply I/O error message sent to the bus coupler
I/O supply failure Message in the diagnostic code (in the IB IL format)
Overrange or underrange Message in the diagnostic code (in the IB IL format)
Configuration invalid Message in the diagnostic code (in the IB IL format)

Interfaces

DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kbps
Transmission physicsCopper

Inline potentials

DesignationCommunications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current consumptiontyp. 55 mA
max. 60 mA
DesignationSupply of analog modules (UANA)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 30 mA
max. 35 mA
Power consumptiontyp. 0.94 W (total)

Analog inputs

Description of the inputDifferential inputs, voltage
Input nameAnalog inputs
Number of inputs4
Connection methodInline connector
Connection technology2-wire
A/D conversion timemax. 6.5 µs
Resolution A/D12 bit
Limit frequency (3 dB)300 Hz
Type of protectionOverload protection
Data formatsIB IL, S7-compatible
Measured value resolution12 bits (11 bits + sign bit)
Measured value representation12 bits (11 bits + sign bit)
Voltage input signal0 V ... 10 V
-10 V ... 10 V
Input resistance of voltage inputtyp. 324 kΩ
Common mode voltage range signal - groundmax. 50 V
FilteringNone or mean-value generation over 4, 16, or 32 measured values

Electrical isolation

Test section5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min.
5 V supply, outgoing remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min.
7.5 V supply (bus logic), 24 V supply UANA/ I/O 500 V AC 50 Hz 1 min.
7.5 V supply (bus logic), 24 V supply UANA/functional earth ground 500 V AC 50 Hz 1 min.
I/O / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values