3 in 1 hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 230 V AC input, 2.4 A output current, emergency stop function, and adjustable overload shutdown. Hybrid start controller for starting motors from 3~ AC up to 550 V AC, with 230 V AC input, 2.4 A output current, emergency stop function and adjustable overload disconnection.

Automation > Motor starter/Motor starter combination
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Degree of protectionIP20

Device supply

Rated control circuit supply voltage US230 V AC (50/60 Hz)
Control supply voltage range85 V AC ... 253 V AC
Rated control supply current IS4 mA
Protective circuitSurge protection

Input data

Input nameControl input right/left
Rated actuating voltage UC230 V AC
Voltage range85 V AC ... 253 V AC
Rated actuating current IC7 mA
Switching threshold44 V AC (“0” signal)
85 V AC (“1” signal)
Switching level< 5 V AC (For EMERGENCY STOP)
Typical turn-off time< 70 ms

Output data load output

Output nameAC output
Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Mains frequency50 Hz
60 Hz
Load current range180 mA ... 2.4 A (see to derating)
Trigger characteristic in acc. with IEC 60947Class 10A
Cooling time20 min. (for auto reset)
Rated operating current at AC-512.4 A
Rated operating current at AC-53a2.4 A
Leakage current0 mA
Protective circuitSurge protection

Output data reply output

Output nameAcknowledge output
NoteConfirmation: floating change-over contact, signal contact
Contact type1 PDT
Switching capacity according to IEC 60947-5-13 A (230 V, AC15)
2 A (24 V, DC13)

General

Switching frequency≤ 2 Hz (Load-dependent)
Mounting positionvertical (horizontal DIN rail, motor output below)
Assembly instructionsalignable, for spacing see derating
Operating mode100% operating factor
Maximum power dissipation4.1 W
Minimum power dissipation0.88 W
Operating voltage displayGreen LED
Status displayYellow LED
IndicationRed LED

Connection data, input side

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm

Connection data, output side

Connection nameLoad circuit
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm

Standards/regulations

DesignationStandards/regulations
Standards/regulationsIEC 60947-1
EN 60947-4-2
IEC 61508
ISO 13849

Insulation characteristics

Rated insulation voltage500 V
Rated surge voltage4 kV
Overvoltage categoryIII
Degree of pollution2
DesignationInsulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
InsulationSafe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC
Safe isolation (EN 50178) at operating voltage ≤ 300 V AC
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
DesignationIsolation characteristics between the control input and control supply voltage to auxiliary circuit
InsulationSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC

Approvals/conformities

Safety Integrity Level according to IEC 61508SIL 3 (safe shutdown)
SIL 2 (motor protection)
Category acc. to EN ISO 138493 (Safe shutdown)
Performance level according to ISO 13849e (Safe shutdown)
ATEX II (2) G [Ex e] [Ex d] [Ex px]
 II (2) D [Ex t] [Ex p]
EU-type examination certificatePTB 07 ATEX 3145

UL data

SCCR100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (480 V AC (fuse: 20 A RK5 (standard fault)))
FLA2.4 A (480 V AC)
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category codeNLDX / NRNT

Standards and Regulations

DesignationStandards/regulations
Standards/regulationsIEC 60947-1
EN 60947-4-2
IEC 61508
ISO 13849
ATEX II (2) G [Ex e] [Ex d] [Ex px]
 II (2) D [Ex t] [Ex p]

eCl@ss

eCl@ss 4.027371102
eCl@ss 4.127371102
eCl@ss 5.027371601
eCl@ss 5.127371601
eCl@ss 6.027371601
eCl@ss 7.027371601
eCl@ss 8.027370905
eCl@ss 9.027370905

ETIM

ETIM 2.0EC000066
ETIM 3.0EC000066
ETIM 4.0EC000066
ETIM 5.0EC002055

UNSPSC

UNSPSC 6.0130211915
UNSPSC 7.090139121514
UNSPSC 1139121514
UNSPSC 12.0139121514
UNSPSC 13.239121514

ETIM for 2900568 Low-voltage industrial controls and switchgear (EC001037)
Feature Name Feature Value
Type of motor starter (EF009598) Direct starter
With short-circuit release (EF006691) No
Rated control supply voltage AC 50 Hz (EF003978) 85 V
Rated control supply voltage AC 60 Hz (EF003979) 85 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie (EF001443) 2.4 A
Rated operation current at AC-3, 400 V (EF009602) 2.4 A
Overload release current setting (EF002336) 0.18 A
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 1
Temperature compensated overload protection (EF009604) No
Release class (EF006668) CLASS 10
Type of electrical connection of main circuit (EF006819) Screw connection
Type of electrical connection for auxiliary- and control current circuit (EF006979) Screw connection
Suitable for rail mounting (EF003972) Yes
Number of command positions (EF001372) 1
Suitable for emergency stop (EF001433) Yes
External reset possible (EF003426) Yes
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 22.5 mm
Height (EF000040) 107 mm
Depth (EF000049) 114 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.