View larger
PLC-BPT-24DC/ 1IC/ACT
2900260
PHOENIX CONTACT
10 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2900260 |
|---|---|
| Packing unit | 10 pc |
| GTIN | 4046356512398 |
| Weight per Piece (excluding packing) | 44.100 g |
| Custom tariff number | 85366990 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|---|
| Note | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. |
| The PLC-ATP separating plate should be installed for safe isolation between adjacent modules | |
| The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. | |
| The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
| Ambient temperature (operation) | -40 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | ≤ 2000 m |
| Compatible components | Miniature relay, REL-MR-24DC/1IC/ACT; miniature optocoupler, OPT-24DC/24DC/5, OPT-24DC/230AC/2 |
|---|
| Connection name | Input side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² () | |
| 2x 0.5 mm² ... 1 mm² () | |
| Conductor cross section AWG | 26 ... 14 |
| Connection name | Output side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² () | |
| 2x 0.5 mm² ... 1 mm² () | |
| Conductor cross section AWG | 26 ... 14 |
| Note | Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. |
|---|---|
| The PLC-ATP separating plate should be installed for safe isolation between adjacent modules | |
| The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. | |
| The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. | |
| Color | gray |
| Operating mode | 100% operating factor |
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Test voltage relay winding/relay contact | 4 kVrms(50 Hz, 1 min.) |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Connection in acc. with standard | CUL |
|---|---|
| Standards/regulations | EN 50178 |
| EN 61810-1 | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 6 kV |
| Insulation | Safe isolation, reinforced insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V0 |
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Feature Name | Feature Value |
|---|---|
| Type of electric connection (EF003961) | Other |
| Mounting method (EF000003) | Other |
| With detachable clamps (EF003340) | No |
| Function extension possible (EF003444) | No |
| Number of pins (EF005580) | 8 |
| Width (EF000008) | 14 mm |
| Height (EF000040) | 80 mm |
| Depth (EF000049) | 94 mm |