Double-deck terminal block conductive protection, number of connections: 4, number of poles: 1, connection type: Push-X connection, Sizing cross-section: 2.5 mm², cross-section: 0.5 mm² - 4 mm², mounting class: NS 35/7.5, NS 35/15, color: yellow-green Double-deck terminal block with protective conductor, number of connections: 4, number of poles: 2, connection type: Push-X connection, dimensioning cross-section: 2.5 mm², cross-section: 0.5 mm² - 4 mm², installation type: NS 35/7.5, NS35/15, colour: yellow-green

Automation > Ground terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Double-deck terminal block conductive protection such as the Phoenix Contact XTTB 2,5-PE provides space-saving grounding solutions within dense electrical enclosures. Multi-level architectures allow technicians to manage protective conductor wiring efficiently without increasing the overall footprint on the mounting rail.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product Type: Grounding terminal block
  • Number of poles: 2
  • Number of connections: 4
  • Number of rows: 2
  • Insulation Properties Surge Category: Iii
  • Degree of pollution: 3
  • Dimensioning Transient Voltage: 8 kV
  • Maximum Dissipated Power with Nominal Condition: 0.77 W
  • Number of connections per floor: 2
  • Nominal Section: 2.5 mm²
  • AWG Conductor Section: (Converted according to IEC)
  • Peel Length: 10 mm ... 12 mm
  • Standard-compliant connection: IEC 60947-7-2
  • Rigid conductor section: 0.5 mm² ... 4 mm²
  • AWG Conductor Section: 20 ... 12 (Converted according to IEC)
  • Flexible conductor section: 0.75 mm² ... 4 mm²

More info

▲
Technical data

Item Properties
Product TypeGrounding terminal block
Number of poles2
Number of connections4
Number of rows2
Insulation Properties
Surge CategoryIii
Degree of pollution3

Electrical Properties
Dimensioning Transient Voltage8 kV
Maximum Dissipated Power with Nominal Condition0.77 W

Connection data
Number of connections per floor2
Nominal Section2.5 mm²
AWG Conductor Section(Converted according to IEC)
Peel Length10 mm ... 12 mm
Standard-compliant connectionIEC 60947-7-2
Rigid conductor section0.5 mm² ... 4 mm²
AWG Conductor Section20 ... 12 (Converted according to IEC)
Flexible conductor section0.75 mm² ... 4 mm²
Flexible Wire Section [AWG]18 ... 12 (Converted according to IEC)
Flexible cable section (toe cap without plastic sleeve)0.5 mm² ... 2.5 mm²
Flexible cable section (toe cap with plastic sleeve)0.5 mm² ... 2.5 mm²
Nominal Section2.5 mm²

Dimensions
Width5.2 mm
Lid Width2.2 mm
Height90 mm
Depth46.1 mm
Depth at NS 35/7.547.6 mm
Depth at NS 35/1555.1 mm

Material Data
ColourGreen
Flammability class according to UL 94V0
Insulating material groupI
Insulating materialPA
Static use of cold insulating material-60 °C
Relative Insulating Material Temperature Index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Flammability of NFPA 130 Surfaces (ASTM E 162)approved
NFPA 130 Specific Optical Flue Gas Density (ASTM E 662)approved
NFPA 130 Flue Gas Toxicity (SMP 800C)approved

Environmental and life-life conditions
Broadband Oscillation/Noise
Test SpecificationDIN EN 50155 (VDE 0115-200):2022-06
SpectrumCategory 2 durability test, on the bogie
frequencyf1= 5 Hz to f2= 250 Hz
ASD Level6.12 (m/s²)²/Hz
Acceleration3.12g
Test duration per axis5 h
Test DirectionsX, Y, and Z axes
ResultApproved Test
Crash
Test SpecificationDIN EN 50155 (VDE 0115-200):2022-06
Shock TypeSemi-sinusoid
Acceleration30g
Duration of the crash18 ms
Number of collisions per steering3
Test DirectionsX, Y, and Z axes (pos. and neg.)
ResultApproved Test
Environmental conditions
Ambient Temperature (Service)-60 °C ... 105 °C (for max. short-term operating temperature, see RTI Elec.)
Ambient Temperature (Storage/Transport)-25 °C ... 60 °C (for a short time, no more than 24 hours, -60 °C to +70 °C)
Ambient Temperature (Mounting)-5 °C ... 70 °C
Ambient Temperature (Drive)-5 °C ... 70 °C
Permissible air humidity (storage/transport)30 % ... 70 %

Standards & Specifications
Standard-compliant connectionIEC 60947-7-2

assembly
Type of mountingNS 35/7.5
NS 35/15

Product Datasheet