View larger
XT 2,5-QUATTRO 1343129 PHOENIX CONTACT Feed-through terminal, nominal voltage: 800 V, nominal current: 24 A,..
XT 2,5-QUATTRO
1343129
PHOENIX CONTACT
50 Pcs.
Automation > Feed-through terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for multi-conductor routing, the Phoenix Contact XT 2,5-QUATTRO feed-through terminal helps engineers organize complex control wiring inside industrial enclosures. Multi-conductor terminal blocks simplify signal distribution by allowing multiple wires to interconnect securely within a single modular housing unit. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Multi-conductor terminal block
- Number of poles: 1
- Field of Employment: Railway industry
- Number of connections: 4
- Number of rows: 1
- Potential: 1
- Insulation Properties Surge Category: Iii
- Degree of pollution: 3
- Dimensioning Transient Voltage: 8 kV
- Maximum Dissipated Power with Nominal Condition: 0.77 W
- Number of connections per floor: 4
- Nominal Section: 2.5 mm²
- AWG Conductor Section: (Converted according to IEC)
- Peel Length: 10 mm ... 12 mm
- Standard-compliant connection: IEC 60947-7-1
- Rigid conductor section: 0.5 mm² ... 4 mm²
More info
▲| General | |
| Observation | The maximum load current must not be exceeded by the total current of all connected conductors. |
| Product Type | Multi-conductor terminal block |
| Number of poles | 1 |
| Field of Employment | Railway industry |
| Machine building | |
| Plant construction | |
| Process Industry | |
| Number of connections | 4 |
| Number of rows | 1 |
| Potential | 1 |
| Insulation Properties | |
| Surge Category | Iii |
| Degree of pollution | 3 |
| Dimensioning Transient Voltage | 8 kV |
| Maximum Dissipated Power with Nominal Condition | 0.77 W |
| Number of connections per floor | 4 |
| Nominal Section | 2.5 mm² |
| AWG Conductor Section | (Converted according to IEC) |
| Peel Length | 10 mm ... 12 mm |
| Standard-compliant connection | IEC 60947-7-1 |
| Rigid conductor section | 0.5 mm² ... 4 mm² |
| AWG Conductor Section | 20 ... 12 (Converted according to IEC) |
| Flexible conductor section | 0.75 mm² ... 4 mm² |
| Flexible Wire Section [AWG] | 18 ... 12 (Converted according to IEC) |
| Flexible cable section (toe cap without plastic sleeve) | 0.5 mm² ... 2.5 mm² |
| Flexible cable section (toe cap with plastic sleeve) | 0.5 mm² ... 2.5 mm² |
| Nominal current | 24 A |
| Maximum Charging Current | 28 A (with rigid 4 mm² cable cross-section) |
| Nominal voltage | 800 V |
| Nominal Section | 2.5 mm² |
| Width | 5.2 mm |
| Height | 72.2 mm |
| Depth | 35.3 mm |
| Depth at NS 35/7.5 | 36.8 mm |
| Depth at NS 35/15 | 44.3 mm |
| Colour | grey |
| Flammability class according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static use of cold insulating material | -60 °C |
| Relative Insulating Material Temperature Index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Flammability of NFPA 130 Surfaces (ASTM E 162) | approved |
| NFPA 130 Specific Optical Flue Gas Density (ASTM E 662) | approved |
| NFPA 130 Flue Gas Toxicity (SMP 800C) | approved |
| Impulse Voltage Test | |
| Result | Approved Test |
| Heating Verification | |
| Heating test requirement | Temperature rise ≤ 45 K |
| Result | Approved Test |
| Short-term permissible current 2.5 mm² | 0.3 kA |
| Result | Approved Test |
| Dielectric Strength with Operating Frequency | |
| Test Voltage Nominal Value | 2 kV |
| Result | Approved Test |
| Mechanical data | |
| Open sidewall | Yes |
| Mechanical resistance | |
| Result | Approved Test |
| Fixing on the bracket | |
| Rail/Fixing Surface | NS 35 |
| Result | Approved Test |
| Checking for damage to conductors and loosening | |
| Rotation speed | 9 r.p.m. |
| Rotations | 135 |
| Conductor Section/Weight | 0.5 mm2/0.3 kg |
| 2.5 mm2/0.7 kg | |
| 4 mm2/0.9 kg | |
| Result | Approved Test |
| Aging | |
| Temperature Cycles | 192 |
| 192 | |
| Result | Approved Test |
| Approved Test | |
| Needle Flame Test | |
| Performance Time | 30 sec |
| Result | Approved Test |
| Broadband Oscillation/Noise | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Spectrum | Category 2 durability test, on the bogie |
| frequency | f1= 5 Hz to f2= 250 Hz |
| ASD Level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axis | 5 h |
| Test Directions | X, Y, and Z axes |
| Result | Approved Test |
| Crash | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Shock Type | Semi-sinusoid |
| Acceleration | 30g |
| Duration of the crash | 18 ms |
| Number of collisions per steering | 3 |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Result | Approved Test |
| Environmental conditions | |
| Ambient Temperature (Storage/Transport) | -25 °C ... 60 °C (for a short time, no more than 24 hours, -60 °C to +70 °C) |
| Ambient Temperature (Mounting) | -5 °C ... 70 °C |
| Ambient Temperature (Drive) | -5 °C ... 70 °C |
| Permissible air humidity (storage/transport) | 30 % ... 70 % |
| Standard-compliant connection | IEC 60947-7-1 |
| Type of mounting | NS 35/7.5 |
| NS 35/15 |