View larger
XT 2,5-PE 1343116 PHOENIX CONTACT Ground terminal, number of connections: 2, number of poles: 1, connection ..
XT 2,5-PE
1343116
PHOENIX CONTACT
50 Pcs.
Automation > Ground terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact XT 2,5-PE ground terminal is a DIN rail-mounted component used to establish secure, low-resistance protective earth connections within industrial control cabinets and distribution boards. Terminal blocks of this type route fault currents safely to the mounting rail, ensuring compliance with electrical safety standards.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Grounding terminal block
- Number of poles: 1
- Field of Employment: Railway industry
- Number of connections: 2
- Number of rows: 1
- Insulation Properties Surge Category: Iii
- Degree of pollution: 3
- Dimensioning Transient Voltage: 8 kV
- Maximum Dissipated Power with Nominal Condition: 0.77 W
- Grounding foot: Yes
- Number of connections per floor: 2
- Nominal Section: 2.5 mm²
- AWG Conductor Section: (Converted according to IEC)
- Peel Length: 10 mm ... 12 mm
- Standard-compliant connection: IEC 60947-7-2
- Rigid conductor section: 0.5 mm² ... 4 mm²
More info
▲| Product Type | Grounding terminal block |
| Number of poles | 1 |
| Field of Employment | Railway industry |
| Machine building | |
| Plant construction | |
| Process Industry | |
| Number of connections | 2 |
| Number of rows | 1 |
| Insulation Properties | |
| Surge Category | Iii |
| Degree of pollution | 3 |
| Dimensioning Transient Voltage | 8 kV |
| Maximum Dissipated Power with Nominal Condition | 0.77 W |
| Grounding foot | Yes |
| Number of connections per floor | 2 |
| Nominal Section | 2.5 mm² |
| AWG Conductor Section | (Converted according to IEC) |
| Peel Length | 10 mm ... 12 mm |
| Standard-compliant connection | IEC 60947-7-2 |
| Rigid conductor section | 0.5 mm² ... 4 mm² |
| AWG Conductor Section | 20 ... 12 (Converted according to IEC) |
| Flexible conductor section | 0.75 mm² ... 4 mm² |
| Flexible Wire Section [AWG] | 18 ... 12 (Converted according to IEC) |
| Flexible cable section (toe cap without plastic sleeve) | 0.5 mm² ... 2.5 mm² |
| Flexible cable section (toe cap with plastic sleeve) | 0.5 mm² ... 2.5 mm² |
| Nominal Section | 2.5 mm² |
| Width | 5.2 mm |
| Lid Width | 2.2 mm |
| Height | 48.6 mm |
| Depth | 35.3 mm |
| Depth at NS 35/7.5 | 36.8 mm |
| Depth at NS 35/15 | 44.3 mm |
| Colour | Green |
| Flammability class according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static use of cold insulating material | -60 °C |
| Relative Insulating Material Temperature Index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Flammability of NFPA 130 Surfaces (ASTM E 162) | approved |
| NFPA 130 Specific Optical Flue Gas Density (ASTM E 662) | approved |
| NFPA 130 Flue Gas Toxicity (SMP 800C) | approved |
| Mechanical data | |
| Open sidewall | Yes |
| Broadband Oscillation/Noise | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Spectrum | Category 2 durability test, on the bogie |
| frequency | f1= 5 Hz to f2= 250 Hz |
| ASD Level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axis | 5 h |
| Test Directions | X, Y, and Z axes |
| Result | Approved Test |
| Crash | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
| Shock Type | Semi-sinusoid |
| Acceleration | 30g |
| Duration of the crash | 18 ms |
| Number of collisions per steering | 3 |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Result | Approved Test |
| Environmental conditions | |
| Ambient Temperature (Service) | -60 °C ... 105 °C (for max. short-term operating temperature, see RTI Elec.) |
| Ambient Temperature (Storage/Transport) | -25 °C ... 60 °C (for a short time, no more than 24 hours, -60 °C to +70 °C) |
| Ambient Temperature (Mounting) | -5 °C ... 70 °C |
| Ambient Temperature (Drive) | -5 °C ... 70 °C |
| Permissible air humidity (storage/transport) | 30 % ... 70 % |
| Standard-compliant connection | IEC 60947-7-2 |
| Type of mounting | NS 35/7.5 |
| NS 35/15 |