Phoenix Contact VS-M12FSBP-M12MS-936-LI/1,14 is a network cable engineered for data communication links within industrial automation architectures. Assemblies of this type facilitate seamless device interconnection across complex machinery networks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of data contacts (EF012232): 0
- Number of power contacts (EF012216): 0
- Number of control contacts (EF012217): 4
- Rated current In (EF008250): 4 A
- Ambient temperature (EF002386): -25 °C
- Rated voltage (EF000228): 48 V
- Over voltage category (EF006785): II
- With protective conductor (EF007468): No
- Degree of protection (IP), mounted (EF007466): IP65
- Screened (EF000881): No
- With status indication (EF001602): No
More info
▲Key Commercial Data
| Orderkey | 1403162 |
|---|---|
| Packing unit | 1 pc |
| Minimum order quantity | 50 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4046356641760 |
| Weight per Piece (excluding packing) | 141.300 g |
| Custom tariff number | 85444290 |
| Country of origin | PL (Poland) |
Ambient conditions
| Degree of protection | IP65 |
|---|---|
| IP67 | |
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
| -40 °C ... 90 °C (cable, fixed installation) | |
| -25 °C ... 90 °C (cable, flexible installation) |
General data
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 250 V |
| Number of positions | 4 |
| Signal type/category | PROFINET CAT5 (IEC 11801), 100 Mbps |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Overvoltage category | II |
Characteristics head 1
| Head type | Plug straight M12 SPEEDCON / IP67 |
|---|---|
| No. of positions (pin connector pattern) | 4 |
| Coding | D (Data) |
| Color | black |
| Material (component) | CuSn (Contact) |
| Ni/Au (Contact surface) | |
| PA (Contact carriers) | |
| TPU, hardly inflammable, self-extinguishing (Grip) | |
| Zinc die-cast, nickel-plated (Screw connection) | |
| Insulation resistance | ≥ 100 MΩ |
| Insertion/withdrawal cycles | ≥ 100 |
| Torque | 0.4 Nm |
| Ambient temperature (operation) | -25 °C ... 90 °C |
Characteristics head 2
| Head type | Flush-type socket straight M12 / IP67 |
|---|---|
| No. of positions (pin connector pattern) | 4 |
| Coding | D (Data) |
| Material (component) | CuZn (Contact) |
| Ni/Au (Contact surface) | |
| PA 6.6 (Contact carriers) | |
| FKM (O-ring) | |
| Zinc die-cast, nickel-plated (Housing) | |
| Insertion/withdrawal cycles | ≥ 100 |
| Ambient temperature (operation) | -40 °C ... 85 °C |
Cable
| Cable type | PROFINET railway applications |
|---|---|
| Cable type (abbreviation) | 936 |
| Signal type/category | PROFINET CAT5 (IEC 11801), 100 Mbps |
| Cable structure | 1x4xAWG22/7; SF/TQ |
| Conductor cross section | 4x 0.34 mm² |
| AWG signal line | 22 |
| Conductor structure signal line | 7x 0.25 mm |
| Core diameter including insulation | 1.95 mm |
| Wire colors | white-blue, orange-yellow |
| Overall twist | Star quad |
| Shielding | Plastic-coated aluminum foil, tinned copper braided shield |
| Optical shield covering | 100 % |
| External sheath, color | black RAL 9005 |
| Outer sheath thickness | ≥ 0.8 mm |
| External cable diameter D | 7.25 mm ±0,3 mm |
| Minimum bending radius, fixed installation | 6 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Cable weight | 81 g/m |
| Outer sheath, material | PE-X |
| Material conductor insulation | PE-X |
| Conductor material | silver-plated Cu litz wires |
| Conductor resistance | ≤ 54.4 Ω/km |
| Working capacitance | ≤ 65 pF (core-core) |
| ≤ 100 pF (core-shield) | |
| Wave impedance | 100 Ω ±5 Ω (f = 100 MHz) |
| Near end crosstalk attenuation (NEXT) | 80 dB (with 1 MHz) |
| 76 dB (at 4 МHz) | |
| 67 dB (at 10 MHz) | |
| 60 dB (at 31.5 МHz) | |
| 56 dB (at 62.5 МHz) | |
| 53 dB (at 100 MHz) | |
| Remote crosstalk attenuation (FEXT) | 80 dB (with 1 MHz) |
| 70 dB (at 4 МHz) | |
| 65 dB (at 10 MHz) | |
| 58 dB (at 31.5 МHz) | |
| 59 dB (at 62.5 МHz) | |
| 67 dB (at 100 MHz) | |
| Attenuation | 2 dB (with 1 MHz) |
| 4 dB (at 4 МHz) | |
| 6.5 dB (at 10 MHz) | |
| 10.5 dB (at 31.5 МHz) | |
| 14 dB (at 62.5 МHz) | |
| 18 dB (at 100 MHz) | |
| Return loss (RL) | 35 dB (at 4 МHz) |
| 35 dB (at 10 MHz) | |
| 35 dB (at 31.5 МHz) | |
| 33 dB (at 62.5 МHz) | |
| 33 dB (at 100 MHz) | |
| Signal speed | 66 c |
| Shield attenuation | 40 dB (30 MHz ≤ f ≤ 100 MHz) |
| Coupling resistance | 200.00 mΩ/m (f ≤ 30 MHz) |
| Nominal voltage, cable | 300 V AC |
| Test voltage, cable | 2000 V AC (50 Hz, 5 minutes) |
| Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
| GM/RT 2130 (Category Ia, Ib, II) | |
| EN 45545 (Risk level HL1 - HL3) | |
| DIN 5510 (Fire protection level 1, 2, 3, 4) | |
| NF F16-101 (Category A1, A2, B) | |
| NF F16-101 (Class C/F0) | |
| NFPA 130 | |
| UNI CEI 11170 (Risk level LR1 - LR4) | |
| Flame resistance | EN 60332-1-2 |
| EN 50266 | |
| EN 60332-3-25 | |
| NF C32-070, 2.1 | |
| NF C32-070, 2.2 | |
| UL 1685, 12 (FT4) | |
| in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) | |
| Halogen-free | According to EN 50267-2-1 |
| Resistance to oil | according to IRM 902, 72 h at 100 °C |
| Other resistance | Resistance to fuels according to IRM 903, 168 h at 70 °C |
| Concentration of fumes | BS 6853 D.8.7 |
| EN 61034-2 | |
| UL 1685, 12 (FT4) | |
| Fume corrosiveness | EN 50267-2-2 |
| Fume toxicity | BS 6853 B.1 |
| EN 50305, 9.2 | |
| Ambient temperature (operation) | -50 °C ... 90 °C (cable, fixed installation) |
| -40 °C ... 90 °C (cable, flexible installation) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |