View larger
VIP-PA-2X14/26/ 2,0M/1756/062 1162593 PHOENIX CONTACT VARIOFACE VIP front adapter, with connected system cab..
VIP-PA-2X14/26/ 2,0M/1756/062
1162593
PHOENIX CONTACT
1 Pcs.
Automation > Accessories/spare parts for controls
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A front adapter with connected system cable such as the Phoenix Contact VIP-PA-2X14/26/ 2,0M/1756/062 bridges programmable logic controllers and marshalling panels by plugging directly into high-density I/O modules to route signals efficiently. This pre-assembled interface link minimizes manual wiring time during control cabinet installation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Front adapter
- Product family: VARIOFACE Professional
- Max. permissible operating voltage: 120 V AC
- Max. permissible current: 1 A (per path)
- Cross section AWG: (converted acc. to IEC)
- Controller level Connection method: Plug-in connection
- Note: Can be plugged onto 20-pos. I/O modules
- Field level Connection in acc. with standard: IEC 60603-13
- Connection method: IDC/FLK socket strip
- Number of connections: 2
- Number of positions: 14
- Pitch: 2.54 mm
- Supply Connection method: Push-in / plug connection
- Stripping length: 9 mm
- Conductor cross section rigid: 0.14 mm² ... 1.5 mm²
- Conductor cross section flexible: 0.14 mm² ... 1.5 mm²
More info
▲| Product type | Front adapter |
| Product family | VARIOFACE Professional |
| Max. permissible operating voltage | 120 V AC |
| Max. permissible current | 1 A (per path) |
| 3 A (per group, positive terminals) | |
| 8 A (per group, negative terminals) | |
| Supported controller ALLEN-BRADLEY ControlLogix | |
| Suitable I/O card | 1756-IA16 |
| 1756-IB16 | |
| 1756-IC16 | |
| 1756-IN16 | |
| Cross section AWG | (converted acc. to IEC) |
| Controller level | |
| Connection method | Plug-in connection |
| Note | Can be plugged onto 20-pos. I/O modules |
| Field level | |
| Connection in acc. with standard | IEC 60603-13 |
| Connection method | IDC/FLK socket strip |
| Number of connections | 2 |
| Number of positions | 14 |
| Pitch | 2.54 mm |
| Supply | |
| Connection method | Push-in / plug connection |
| Stripping length | 9 mm |
| Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| Conductor cross section AWG | 26 ... 16 |
| Item dimensions | |
| Width | 344.822 mm |
| Height | 47.352 mm |
| Depth | 56.345 mm |
| Cable | |
| Length | 2 m |
| 14X0.14 [PVC] | |
| UL AWM Style | 2464/1061 |
| Number of positions | 14 |
| Shielded | no |
| Cable type | 14X0.14 [PVC] |
| Conductor type | Round cable set |
| Conductor structure signal line | 7x 0.16 mm |
| AWG signal line | 26 |
| Conductor cross section | 14x 0.14 mm² |
| Wire diameter incl. insulation | 1 mm ±0.03 mm |
| External cable diameter | 6.4 mm ±0.4 mm |
| Outer sheath, material | Semi-rigid PVC |
| External sheath, color | gray |
| Conductor material | Tin-plated Cu litz wires |
| Cable resistance | ≤ 145 Ω/km (20 °C) |
| Insulation resistance | ≥ 20 MΩ*km (20 °C) |
| Smallest bending radius, fixed installation | 55 mm |
| Smallest bending radius, movable installation | 104 mm |
| Max. bending cycles | 5000 (at a radius of ≥ 15x outside diameter) |
| Halogen-free | no |
| Flame resistance | IEC 60332-1-2 (raw cable) |
| VDE 0842, Part 332-1-2 (raw cable) | |
| IEC 60332-3-22 (raw cable) | |
| UL VW-1 | |
| CSA FT-1 | |
| Resistance to oil | can withstand occasional splashes (raw cable) |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | 0 °C ... 60 °C |
| Ambient temperature (storage/transport) | 0 °C ... 80 °C |
| Altitude | ≤ 2000 m (Above sea level) |
| Permissible humidity (operation) | ≤ 95 % (non-condensing) |
| Standards/regulations | UL 61010-2-201 |
| General | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |