View larger
VIP-CAB-FLK50/21,0M/S/SC057 1098755 PHOENIX CONTACT Assembled shielded round cable with additional shield co..
VIP-CAB-FLK50/21,0M/S/SC057
1098755
PHOENIX CONTACT
1 Pcs.
Cables > PLC connection cable
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact VIP-CAB-FLK50/21,0M/S/SC057 is an assembled shielded round cable with additional shield connection designed for internal control cabinet wiring and secure signal transmission between system components. Control cables of this type link industrial automation hardware, input/output modules, and interface blocks while minimizing electrical interference in complex setups. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1098755
- Packing unit: 1
- GTIN: 4055626944654
- Custom tariff number: 85444290
- Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Maximum altitude: ≤ 2000 m
- Degree of protection: IP20
- Max. permissible operating voltage: 24 V DC
- Max. current carrying capacity per path: 0.5 A
- Length of cable: 21 m
- External cable diameter: 11 mm ±0,3 mm
- Single wire, cross section: 0.14 mm²
- Single wire, cross section [AWG]: 26
- Single wire, number of litz wires: 7
- Single wire, material: Cu tin-plated
More info
▲Ambient conditions
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
|---|---|
| -10 °C ... 70 °C (flexible installation) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Maximum altitude | ≤ 2000 m |
| Degree of protection | IP20 |
| ≥ IP54 (Installation location) |
General
| Max. permissible operating voltage | 24 V DC |
|---|---|
| Max. current carrying capacity per path | 0.5 A |
| Length of cable | 21 m |
| External cable diameter | 11 mm ±0,3 mm |
| Single wire, cross section | 0.14 mm² |
| Single wire, cross section [AWG] | 26 |
| Single wire, number of litz wires | 7 |
| Single wire, material | Cu tin-plated |
| Wire diameter incl. insulation | 1 mm ±0.03 mm |
| Smallest bending radius, fixed installation | 113 mm |
| Smallest bending radius, movable installation | 203 mm |
| Bending cycles | 5000 (at a radius of ≥ 18x outside diameter) |
| Cable, preassembly | Insulation displacement, IEC 60352-4/DIN EN 60352-4 |
| Shielding | yes |
| Tinned copper-braided shield, approx. 85% covering | |
| Cable insulation resistance | ≥ 20 MΩ/km (20 °C) |
| Cable resistance | ≤ 145 Ω/km (at 20 °C) |
| Outer sheath, material | PVC |
| External sheath, color | gray RAL 7035 |
| Nominal operating mode | 100% operating factor |
Connection data
| Connection name | Flat-ribbon cable connector |
|---|---|
| Connection in acc. with standard | IEC 60603-13 |
| Connection method | IDC/FLK socket strip |
| Number of connections | 1 |
| Number of positions | 50 |
| Exit angle | 180 ° |
| Insertion/withdrawal cycles | > 200 |
| Pitch | 2.54 mm |
Connection data 2
| Connection name | Flat-ribbon cable connector |
|---|---|
| Connection in acc. with standard | IEC 60603-13 |
| Connection method | IDC/FLK socket strip |
| Number of connections | 1 |
| Number of positions | 50 |
| Exit angle | 180 ° |
| Insertion/withdrawal cycles | > 200 |
| Pitch | 2.54 mm |
Standards and Regulations
| Flame resistance | according to IEC 60332-1 |
|---|---|
| According to CSA FT1 | |
| in acc. to UL VW1 | |
| Resistance to oil | against occasional splashes |
| Gasoline resistance | against occasional splashes |
| Designation | Air clearances and creepage distances |
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 50 V |
| Rated surge voltage | 0.5 kV (1.2/50 μs) |
| Insulation | Functional insulation |
| Pollution degree | 2 |
| Overvoltage category | II |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |