Designed to safeguard electrical circuits in North American regional layouts, the Phoenix Contact VAL-US-240D/40-P (2910337) operates as a Type 2 surge protection plug. Industrial control panels and distribution systems utilize such modular suppression devices to divert harmful voltage spikes safely to ground. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2910337
- Packing unit: 1 pc
- Note: Made to Order (non-returnable)
- GTIN: 4055626444499
- Weight per Piece (excluding packing): 39.000 g
- Custom tariff number: 85363030
- Country of origin: US (United States)
- Height: 52.4 mm
- Width: 17.5 mm
- Depth: 55.3 mm
- Horizontal pitch: 1 Div.
- Degree of protection: IP20
- Ambient temperature (operation): -40 °C ... 80 °C
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Altitude: ≤ 2000 m (amsl (above mean sea level))
- Permissible humidity (operation): 5 % ... 95 %
More info
▲Key Commercial Data
| Orderkey | 2910337 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626444499 |
| Weight per Piece (excluding packing) | 39.000 g |
| Custom tariff number | 85363030 |
| Country of origin | US (United States) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
General
| IEC test classification | II |
|---|---|
| T2 | |
| EN type | T2 |
| Mode of protection | L-L |
| L-PEN | |
| Mounting type | on base element |
| Color | jet black RAL 9005 |
| Housing material | PA 6.6 |
| PBT | |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Type | Male |
| Number of positions | 1 |
| Surge protection fault message | optical |
Protective circuit
| Nominal voltage UN | 240/415 V AC (TN) |
|---|---|
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous voltage UC | 275 V AC |
| Residual current IPE | ≤ 450 µA |
| Standby power consumption PC | ≤ 120 mVA |
| Nominal discharge current In(8/20) µs | 20 kA |
| Maximum discharge current Imax(8/20) µs | 40 kA |
| Short-circuit current rating ISCCR | 25 kA |
| Voltage protection level Up | ≤ 1.35 kV |
| Residual voltage Ures | ≤ 1.35 kV (at In) |
| ≤ 1.1 kV (at 10 kA) | |
| ≤ 1 kV (at 5 kA) | |
| ≤ 0.9 kV (at 3 kA) | |
| TOV behavior at UT | 335 V AC (5 s / withstand mode) |
| 440 V AC (120 min / safe failure mode) | |
| Max. backup fuse with branch wiring | 100 A (gG) |
UL specifications
| SPD Type | 1CA |
|---|---|
| Maximum continuous operating voltage MCOV | 275 V AC |
| Nom. voltage | 240 V AC (Delta) |
| Mode of protection | L-L |
| L-G | |
| Power distribution system | Single phase |
| Nominal frequency | 50/60 Hz |
| Voltage protection rating VPR | 1000 V |
| Nominal discharge current In | 20 kA |
| Maximum Surge Current per Phase | 40 kA |
| Short-circuit current rating (SCCR) | 200 kA |