VAL-MS 690 ST 1068842 PHOENIX CONTACT Type 2 surge protection plug with high-capacity varistor for VAL-MS ba..
VAL-MS 690 ST
1068842
PHOENIX CONTACT
1 Pcs.
Automation > Accessories/spare parts for surge protection power supply systems
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This VAL-MS 690 ST 1068842 PHOENIX CONTACT Type 2 surge protection plug with high-capacity varistor for VAL-MS ba.. acts as a primary defense element against high-energy electrical surges. Industrial installations rely on these pluggable surge devices to absorb transient voltage spikes and maintain system reliability across heavy industrial zones. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1068842
- Packing unit: 1
- GTIN: 4055626743905
- Custom tariff number: 85363010
- Height: 52.4 mm
- Width: 17.5 mm
- Depth: 55.3 mm
- Horizontal pitch: 1 Div.
- Degree of protection: IP20
- Ambient temperature (operation): -40 °C ... 85 °C
- Ambient temperature (storage/transport): -40 °C ... 85 °C
- Altitude: ≤ 2000 m (amsl (above mean sea level))
- Permissible humidity (operation): 5 % ... 95 %
- Shock (operation): 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
- Vibration (operation): 5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
- IEC test classification: II
More info
▲Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 85 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
General
| IEC test classification | II |
|---|---|
| T2 | |
| EN type | T2 |
| IEC power supply system | TN |
| IT | |
| Mode of protection | L-PE (IT) |
| L-PEN (TN-C) | |
| Mounting type | on base element |
| Color | jet black RAL 9005 |
| Housing material | PA 6.6 |
| Degree of pollution | 2 |
| Distance between live and grounded parts | 8 mm |
| Flammability rating according to UL 94 | V-0 |
| Type | Male |
| Number of positions | 1 |
| Surge protection fault message | optical |
Additional descriptions
| Note | For use in all low-voltage systems between L-PEN. Only for use in IT systems between L-PE if the bodies of the equipment in the low-voltage system are connected to the grounding system of the transformer station. (common grounding of the HV transformer station and the bodies of the LV consumer's installation. RE= RAaccording to IEC 60364-4-442/VDE 0100-442 Figure 44D/example a) |
|---|---|
| A maximum backup fuse (with branch line wiring) of F=250 A gG can be used for systems with a prospective short-circuit current of between 3 kA to 50 kA. |
Protective circuit
| Nominal voltage UN | 554/960 V AC (TN) |
|---|---|
| 690 V AC (IT) | |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous voltage UC | 760 V AC |
| Residual current IPE | ≤ 0.5 mA |
| Standby power consumption PC | ≤ 400 mVA |
| Nominal discharge current In(8/20) µs | 20 kA |
| Maximum discharge current Imax(8/20) µs | 30 kA |
| Short-circuit current rating ISCCR | 25 kA |
| Voltage protection level Up | ≤ 2.9 kV |
| TOV behavior at UT | 1005 V AC (5 s / withstand mode) |
| 1056 V AC (120 min / safe failure mode) | |
| Response time tA | ≤ 25 ns |
| Max. backup fuse with branch wiring | 200 A (gG) |
UL specifications
| SPD Type | 4CA |
|---|---|
| Maximum continuous operating voltage MCOV (L-N) | 750 V AC |
| Nom. voltage | 690 V AC |
| Mode of protection | L-N |
| Power distribution system | Single phase |
| Nominal frequency | 50/60 Hz |
| Measured limiting voltage MLV (L-N) | 3040 V |
| Nominal discharge current In(L-N) | 20 kA |