View larger
VAL-MS 1000DC-PV-ST/4 1019121 PHOENIX CONTACT Type 2 surge protection plug
VAL-MS 1000DC-PV-ST/4
1019121
PHOENIX CONTACT
4 Pcs.
Automation > Accessories/spare parts for surge protection power supply systems
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact VAL-MS 1000DC-PV-ST/4 (1019121) functions as a Type 2 surge protection plug built to handle direct current applications in renewable energy setups. Photovoltaic combiner boxes use these protective modules to prevent lightning-induced surges from damaging expensive inverter electronics. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 1019121
- Packing unit: 4 pc
- Minimum order quantity: 4 pc
- Note: Made to Order (non-returnable)
- GTIN: 4055626504889
- Weight per Piece (excluding packing): 51.200 g
- Custom tariff number: 85363010
- Country of origin: DE (Germany)
- Height: 52.4 mm
- Width: 17.5 mm
- Depth: 55.3 mm
- Horizontal pitch: 1 Div.
- Degree of protection: IP20
- Ambient temperature (operation): -40 °C ... 80 °C
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Altitude: ≤ 2000 m (amsl (above mean sea level))
More info
▲Key Commercial Data
| Orderkey | 1019121 |
|---|---|
| Packing unit | 4 pc |
| Minimum order quantity | 4 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626504889 |
| Weight per Piece (excluding packing) | 51.200 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 60g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 7.5g (5-500 Hz/2.5 h/XYZ) |
General
| IEC test classification | PV II |
|---|---|
| PV T2 | |
| EN type | T2 |
| SPD failure behavior | OCM (Open-circuit mode) |
| Color | jet black RAL 9005 |
| Housing material | PA 6.6-FR |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Type | Male |
| Surge protection fault message | optical |
Protective circuit DC voltage side (DC)
| Maximum continuous operating voltage UCPV | 585 V DC |
|---|---|
| Short-circuit current rating ISCPV | 1000 A |
| Continuous operating current ICPV | < 20 µA |
| Standby power consumption PC | ≤ 25 mVA |
| Nominal discharge current (8/20) µs | 15 kA |
| Maximum discharge current Imax(8/20) µs | 40 kA |
| Voltage protection level Up | ≤ 1.9 kV |
| Residual voltage Ures | ≤ 1.9 kV (at In) |
| ≤ 1.5 kV (at 5 kA) | |
| ≤ 1.7 kV (at 10 kA) | |
| ≤ 2 kV (at 20 kA) | |
| ≤ 2.3 kV (at 30 kA) | |
| ≤ 2.5 kV (at 40 kA) | |
| Response time tA | ≤ 25 ns |
| Insulation resistance Riso | > 5 GΩ (at 500 V DC) |
UL specifications
| SPD Type | 4CA |
|---|---|
| Maximum continuous operating voltage MCOV (L+) - G | 1170 V DC |
| Nominal voltage | 970 V DC |
| Mode of protection | (L+) - G |
| Power distribution system | Single phase |
| Measured limiting voltage MLV (L+) - G | 1980 V |
| Nominal discharge current In(L+) - G | 10 kA |