View larger
UTWE 6/9+1 1029711 PHOENIX CONTACT Test terminal strip
UTWE 6/9+1
1029711
PHOENIX CONTACT
5 Pcs.
Automation > Test plug for terminal blocks
Enclosures connectivity
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
UTWE 6/9+1 1029711 PHOENIX CONTACT Test terminal strip is integrated into switchboards and control cabinets to facilitate safe isolation and diagnostic testing of electrical secondary systems. Such terminal blocks allow technicians to perform measurements without disturbing permanent wiring connections.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Strip length (EF006824): 10 mm
- Rated voltage (EF000228): 400 V
- Connectable conductor cross section solid-core (EF007337): 0.2 mm²
- Connectable conductor cross section multi-wired (EF007343): 0.2 mm²
- Type of electric connection (EF003961): Screw connection
- Connectable (EF006169): No
- Number of poles (EF001391): 10
- Modular spacing (EF000394): 8.2 mm
More info
▲Key Commercial Data
| Orderkey | 1029711 |
|---|---|
| Packing unit | 5 pc |
| Minimum order quantity | 5 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626531533 |
| Weight per Piece (excluding packing) | 22.220 g |
| Custom tariff number | 85369010 |
| Country of origin | PL (Poland) |
General
| Number of positions | 10 |
|---|---|
| Number of levels | 1 |
| Number of connections | 20 |
| Potentials | 10 |
| Nominal cross section | 6 mm² |
| Color | gray |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Maximum load current | 30 A |
| Rated surge voltage | 4 kV |
| Test surge voltage | 5 kV |
| Overvoltage category | III |
| Insulating material group | I |
| Maximum power dissipation for nominal condition | 1.31 W |
| Maximum load current | 30 A (with 10 mm² conductor cross section) |
| Nominal current IN | 24 A |
| Nominal voltage UN | 400 V |
| Open side panel | No |
| Terminal block mounting | 0.8 Nm ... 1 Nm |
Connection data
| Connection method | Screw connection |
|---|---|
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 10 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 8 |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 10 mm² |
| Min. AWG conductor cross section, flexible | 24 |
| Max. AWG conductor cross section, flexible | 8 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 6 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 6 mm² |
| 2 conductors with same cross section, solid min. | 0.2 mm² |
| 2 conductors with same cross section, solid max. | 2.5 mm² |
| 2 conductors with same cross section, stranded min. | 0.2 mm² |
| 2 conductors with same cross section, stranded max. | 2.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. | 0.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 2.5 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. | 0.25 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. | 1.5 mm² |
| Stripping length | 10 mm |
| Internal cylindrical gage | A5 |
| Screw thread | M4 |
| Tightening torque, min | 1.5 Nm |
| Tightening torque max | 1.8 Nm |
Mounting
| Mounting type | Wall mounting |
|---|---|
| Plate thickness | 1 mm ... 4 mm |
| Min. tightening torque of the mounting screw: | 0.8 Nm |
| Max. tightening torque of the mounting screw: | 1 Nm |
Standards and Regulations
| Connection in acc. with standard | IEC 60947-7-1 |
|---|---|
| Flammability rating according to UL 94 | V0 |