View larger
UNO-UPS/24DC/24DC/60W 2905907 PHOENIX CONTACT Uninterruptible power supply
UNO-UPS/24DC/24DC/60W
2905907
PHOENIX CONTACT
1 Pcs.
Automation > UPS
Power Supplies (PS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built as a Phoenix Contact UNO-UPS/24DC/24DC/60W 2905907 PHOENIX CONTACT Uninterruptible power supply, this device provides steady backup energy to keep control loops and automation components operational during brownouts. DC uninterruptible power supplies are vital for maintaining low-voltage control circuits in industrial applications. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 22.5 V
- Output voltage (EF003933): 24 V
- SNMP (EF005284): No
- Voltage type (EF000187): DC
- Height (EF000040): 90 mm
- Width (EF000008): 110 mm
- Depth (EF000049): 84 mm
- Weight (EF000167): 1.186 kg
- Bridging time full load (EF000428): 300 min
More info
▲Key Commercial Data
| Orderkey | 2905907 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 299 (C-4-2017) |
| GTIN | 4055626007380 |
| Weight per Piece (excluding packing) | 1,119.800 g |
| Custom tariff number | 85371091 |
| Country of origin | DE (Germany) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -15 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 60 °C |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Degree of pollution | 2 |
Input data
| Input voltage | 24 V DC |
|---|---|
| Nominal input voltage | 24 V DC (SELV) |
| Input voltage range | 22.5 V DC ... 29.5 V DC |
| Current consumption (charging process) | < 0.3 A (Charging (ICharge = max, IOut = 0)) |
| Current consumption (maximum) | 2.8 A |
| Current consumption (idle) | < 60 mA |
| Input fuse, integrated | 5 A (electronic) |
Output data (24 V DC mains operation)
| Nominal output voltage | 24 V DC |
|---|---|
| Output voltage range (depends on the input voltage) | UOut= UIn- 0.5 V DC |
| Nominal output current (IN) | 2.5 A |
General
| IQ technology | no |
|---|---|
| Net weight | 1 kg |
| Memory medium | Lead rechargeable battery module |
| Protection class | III |
| MTBF (IEC 61709, SN 29500) | > 1900000 h (40 °C) |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions | alignable: 0 mm horizontally, 30 mm vertically |
Connection data, input
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Connection data, output
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Connection data for signaling
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Noise immunity | EN 61000-6-2 |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 4 kV (Test Level 2) |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 80 MHz ... 3 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Standards/regulations | EN 61000-4-6 |
| Frequency range | 0.15 MHz ... 80 MHz |
| Voltage | 10 V (Test Level 3) |
| Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
| UL approvals | UL Listed UL 508 |
| UL/C-UL Recognized UL 60950-1 | |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) | < 13.2 Hz, amplitude ±1.0 mm (according to IEC 60068-2-6) |
| 13.2 Hz ... 100 Hz, 0.7g |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 25; |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |