View larger
PSR-SPP- 24UC/URM/3X1/3X2 2981842 PHOENIX CONTACT Coupling relay
PSR-SPP-24UC/URM/3X1/3X2
2981842
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Phoenix Contact PSR-SPP-24UC/URM/3X1/3X2 coupling relay serves as an essential interface component in industrial automation setups, bridging control signals with heavier load requirements for safe switch-off routines. Coupling relays isolate control circuits from main power paths while allowing auxiliary contacts to multiply signaling pathways in safety-critical loops. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Note on application Note on application: Only for industrial use
- Product type: Coupling relay
- Product family: PSRclassic
- Application: Safe switch off
- Mechanical service life: 10x 10 6 cycles
- Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Data management status Article revision: 06
- Times Restart time: < 1 s (Boot time)
- Nominal operating mode: 100% operating factor
- Supply Rated control circuit supply voltage U S: 20.4 V AC/DC ... 26.4 V AC/DC
- General Rated control circuit supply voltage U S: 24 V AC/DC -15 % / +10 %
- Power consumption at U S: typ. 1.08 W
- Rated control supply current I S: typ. 45 mA
- Input voltage range: 20.4 V AC/DC ... 26.4 V AC/DC
- Inrush current: typ. 350 mA DC (Δt s)
- Typ. starting time with U s: typ. 15 ms (when controlled via A1)
More info
▲| Note on application | |
| Note on application | Only for industrial use |
| Product type | Coupling relay |
| Product family | PSRclassic |
| Application | Safe switch off |
| High demand | |
| Low demand | |
| Mechanical service life | 10x 106cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Data management status | |
| Article revision | 06 |
| Times | |
| Restart time | < 1 s (Boot time) |
| Maximum power dissipation for nominal condition | 6.11 W (at UB= 26.4 V DC, US= 24 V, IS= 45 mA, n = 1, IL² = 48 A², Rcontact= 0.1 ) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V |
| 250 V | |
| Rated surge voltage/insulation | 4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.) |
| Supply | |
| Rated control circuit supply voltage US | 20.4 V AC/DC ... 26.4 V AC/DC |
| General | |
| Rated control circuit supply voltage US | 24 V AC/DC -15 % / +10 % |
| Power consumption at US | typ. 1.08 W |
| Rated control supply current IS | typ. 45 mA |
| Input voltage range | 20.4 V AC/DC ... 26.4 V AC/DC |
| Inrush current | typ. 350 mA DC (Δt s) |
| typ. 350 mA AC (Δt = 2 ms at Us) | |
| Typ. starting time with Us | typ. 15 ms (when controlled via A1) |
| Typical release time | typ. 15 ms (when controlled via A1) |
| Recovery time | < 500 ms |
| Maximum switching frequency | 0.5 Hz |
| Protective circuit | Surge protection; Suppressor diode |
| Operating voltage display | 1 x green LED |
| Contact switching type | 3 enabling current paths |
| 3 confirmation current paths | |
| Contact material | AgSnO2 |
| Maximum switching voltage | 230 V AC/DC (Observe the load curve) |
| Minimum switching voltage | 5 V AC/DC |
| Limiting continuous current | 6 A (N/O contact) |
| 6 A (N/C contact) | |
| Maximum inrush current | 8 A |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 48 A2 |
| Interrupting rating (ohmic load) max. | For additional values, see load curve |
| Maximum interrupting rating (inductive load) | 48 W (N/O contact, 24 V DC, τ = 40 ms) |
| 40 W (N/O contact, 48 V DC, τ = 40 ms) | |
| 36 W (N/O contact, 60 V DC, τ = 40 ms) | |
| 35 W (N/O contact, 110 V DC, τ = 40 ms) | |
| 33 W (N/O contact, 220 V DC, τ = 40 ms) | |
| Switching capacity | min. 50 mW |
| Switching capacity in accordance with IEC 60947-5-1 | 5 A (24 V (DC13)) |
| 5 A (230 V (AC 15)) | |
| Output fuse | 10 A gL/gG (N/O contact) |
| 4 A gL/gG (N/O contact, for low-demand applications) | |
| 6 A gL/gG (N/C contact) |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Push-in connection |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Conductor cross-section AWG | 24 ... 16 |
| Stripping length | 8 mm |
| Tightening torque | 0.6 Nm |
| Width | 22.5 mm |
| Height | 114.5 mm |
| Depth | 112 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | Polyamide |
| Safety data | |
| Stop category | 0 |
| Safety data: EN ISO 13849 | |
| Category | 1 |
| Performance level (PL) | c |
| Safety data: IEC 61508 - High demand | |
| Safety Integrity Level (SIL) | 1 |
| Safety data: IEC 61508 - Low demand | |
| Safety Integrity Level (SIL) | 1 |
| Safety data | |
| Safety Integrity Level (SIL) | 1 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 °C ... 55 °C |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Maximum altitude | max. 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.) |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.) |
| CE | |
| Certificate | CE-compliant |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | DIN EN 50178 |
| Mounting type | DIN rail mounting |
| Mounting position | vertical or horizontal |