The Phoenix Contact PSR-SCF-24UC/URM/2X21 coupling relay is a specialized interface component utilized in safety and control loops to isolate circuits and handle intermediate switching tasks. These devices ensure proper signal transmission and protection in industrial automation environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- Complete with socket (EF003359): Yes
- With detachable clamps (EF003340): No
- With LED indication (EF005950): Yes
- Voltage type for actuating (EF008242): AC/DC
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as change-over contact (EF008257): 2
- With forced-guided contacts (EF003357): No
- Nominal current (EF000001): 0.03 A
- Degree of protection (IP) (EF005474): IP20
- Width (EF000008): 17.5 mm
- Height (EF000040): 75 mm
- Depth (EF000049): 60.5 mm
More info
▲Key Commercial Data
| Orderkey | 2981363 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 279 (C-6-2017) |
| GTIN | 4017918946906 |
| Weight per Piece (excluding packing) | 61.820 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 50 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | 24 V AC/DC -15 % / +10 % |
|---|---|
| Rated control supply current IS | typ. 30 mA |
| Power consumption at US | typ. 0.72 W |
| Inrush current | typ. 350 mA DC (Δt s) |
| typ. 350 mA AC (Δt = 2 ms at Us) | |
| Typ. starting time with Us | typ. 10 ms |
| Typical release time | typ. 10 ms |
| Recovery time | < 500 ms |
| Operating voltage display | 1 x yellow LED |
| Maximum switching frequency | 0.5 Hz |
| Filter time | max. 1.5 ms (at S12; test pulse width) |
| 7.5 ms (at S12; test pulse rate) | |
| Test pulse rate = 5 x Test pulse width |
Output data
| Contact type | 2 PDT |
|---|---|
| Contact material | AgNi |
| Maximum switching voltage | 230 V AC/DC (Observe the load curve) |
| Minimum switching voltage | 5 V AC/DC |
| Limiting continuous current | 5 A (N/O contact) |
| 3.5 A (N/C contact) | |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 50 A2 |
| Interrupting rating (ohmic load) max. | 144 W (N/O contact, 24 V DC, τ = 0 ms) |
| 288 W (N/O contact, 48 V DC, τ = 0 ms) | |
| 88 W (N/O contact, 110 V DC, τ = 0 ms) | |
| 110 W (N/O contact, 220 V DC, τ = 0 ms) | |
| 1500 VA (N/O contact, 230 V AC, τ = 0 ms) | |
| Switching capacity | min. 50 mW |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 3 A (24 V (DC13)) |
| 3 A (250 V (AC15)) | |
| Output fuse | 6 A gL/gG (N/O contact) |
| 4 A gL/gG (N/O contact, for low-demand applications) | |
| 4 A gL/gG (N/C contact) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 61.82 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | green |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | no |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 1 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 1 |
| Designation | EN ISO 13849 |
| Performance level (PL) | c |
| Category | 1 |
| Safety Integrity Level Claim Limit (SIL CL) | 1 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 250 V |
| 250 V | |
| Rated surge voltage/insulation | 4 kV/basic insulation (safe isolation, reinforced insulation, and 6 kV between logic and signaling current paths). |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | N/O contact: 10g, N/C contact: 5g (In the event of stress caused by shock, contact reactions are possible for up to 1 ms.) |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.) |
| Conformance | CE-compliant |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |