View larger
PSR-SCF-120UC/URM/2X21 2981376 PHOENIX CONTACT Extension module
PSR-SCF-120UC/URM/2X21
2981376
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An extension module is an accessory unit used in control panels to expand the input and output capabilities of safety or logic relays. This Phoenix Contact PSR-SCF-120UC/URM/2X21 device integrates seamlessly into industrial installations to help manage auxiliary switching channels and interlock signals. Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- Complete with socket (EF003359): Yes
- With detachable clamps (EF003340): No
- With LED indication (EF005950): Yes
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as change-over contact (EF008257): 2
- With forced-guided contacts (EF003357): No
- Nominal current (EF000001): 0.009 A
- Degree of protection (IP) (EF005474): IP20
- Width (EF000008): 17.5 mm
- Height (EF000040): 75 mm
- Depth (EF000049): 60.5 mm
More info
▲Key Commercial Data
| Orderkey | 2981376 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 279 (C-6-2017) |
| GTIN | 4017918952907 |
| Weight per Piece (excluding packing) | 61.970 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 50 °C |
|---|---|
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Input data
| Nominal input voltage UN | 120 V AC/DC |
|---|---|
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Typical input current at UN | 9 mA |
| Typical response time | 10 ms |
| Typical release time | 10 ms |
Output data
| Contact type | 2 PDT |
|---|---|
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 15 V AC/DC |
| Limiting continuous current | 5 A (N/O contact) |
| 3.5 A (N/C contact) | |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 10 mA |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
| 288 W (48 V DC, τ = 0 ms) | |
| 88 W (110 V DC, τ = 0 ms) | |
| 110 W (220 V DC, τ = 0 ms) | |
| 1500 VA (250 V AC, τ = 0 ms) | |
| Maximum interrupting rating (inductive load) | on request |
| Switching capacity min. | 0.24 W |
| Mechanical service life | approx. 107cycles |
| Switching capacity (360/h cycles) | 6 A (24 V DC; N/O contact) |
| 3 A (230 V AC; N/O contact) | |
| Output fuse | 6 A gL/gG NEOZED (N/O contact) |
| 4 A gL/gG NEOZED (N/C contact) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 61.97 g |
| Mounting position | any |
| Mounting type | DIN rail mounting |
| Degree of protection | IP20 |
| Housing color | green |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | no |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| EN 50205 | |
| Rated insulation voltage | 250 V |
| Rated surge voltage/insulation | 4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.) |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |