View larger
TC-D37SUB-ADIO16-EX-P-UNI 2924854 PHOENIX CONTACT Module carrier
TC-D37SUB-ADIO16-EX-P-UNI
2924854
PHOENIX CONTACT
1 Pcs.
Automation > Interface module
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for demanding process environments, the TC-D37SUB-ADIO16-EX-P-UNI 2924854 PHOENIX CONTACT Module carrier provides a secure mounting and distribution framework for multi-channel signal conditioners. Such carriers ensure reliable power distribution and orderly signal routing between field instrumentation and control systems in hazardous or complex applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Module carrier
- Data management status Article revision: 06
- Overvoltage category: II
- Pollution degree: 2
- Max. permissible current: 1 A (Signal/channel)
- Nominal voltage U N: < 30 V DC (Per signal/channel)
- Rated surge voltage: 0.5 kV
- Supported controller universal Suitable I/O card: universal
- Supply Designation: Power module
- Note: Power supply via 2904673 TC-MACX-MCR-PTB power supply and error signaling module.
- Fuse: 2x 2.5 A on PCB, slow-blow (replaceable)
- Input voltage: 24 V DC
- Input voltage range: 19.2 V DC ... 30 V DC
- Input current: ≤ 2 A
- Redundant supply: yes, decoupled from diodes
- Polarization and surge protection: Yes
More info
▲| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Product type | Module carrier |
| Data management status | |
| Article revision | 06 |
| Insulation characteristics: Air clearances and creepage distances | |
| Insulation | Basic insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
| Max. permissible current | 1 A (Signal/channel) |
| Nominal voltage UN | < 30 V DC (Per signal/channel) |
| Air clearances and creepage distances | |
| Rated insulation voltage | 50 V |
| Rated surge voltage | 0.5 kV |
| Supported controller universal | |
| Suitable I/O card | universal |
| Supply | |
| Designation | Power module |
| Note | Power supply via 2904673 TC-MACX-MCR-PTB power supply and error signaling module. |
| Fuse | 2x 2.5 A on PCB, slow-blow (replaceable) |
| Input voltage | 24 V DC |
| Input voltage range | 19.2 V DC ... 30 V DC |
| Input current | ≤ 2 A |
| Redundant supply | yes, decoupled from diodes |
| Polarization and surge protection | Yes |
| Output name | Switching output |
| Contact switching type | 1 N/C contact (alarm = open) |
| Maximum switching voltage | 50 V DC (0.3 A) |
| 30 V DC (2 A) | |
| 33 V AC (2 A) | |
| Power supply | |
| Connection method | Screw connection |
| Stripping length | 7 mm |
| Number of connections | 1 |
| Number of positions | 6 |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Controller level | |
| Connection method | D-SUB pin strip |
| Number of connections | 1 |
| Number of positions | 37 |
| Status display | 1 x red LED (error) |
| 2x green LEDs (PWR1 and PWR2) |
| Width | 242 mm |
| Height | 170 mm |
| Depth | 159.5 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Ambient conditions | |
| Degree of protection | IP00 |
| Ambient temperature (operation) | -20 °C ... 60 °C (Please observe module specifications) |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Shock | 15g, according to IEC 60068-2-27 |
| Vibration (operation) | 2g, according to IEC 60068-2-6 |
| ATEX | |
| Identification | II 3 G Ex nA IIC T4 Gc X |
| UKCA Ex (UKEX) | |
| Identification | II 3 G Ex nA IIC T4 Gc |
| Certificate | PxCIF21UKEX2924854X |
| UL, USA/Canada | |
| Identification | UL 61010 Listed |
| Class I, Div. 2, Groups A, B, C, D T4 | |
| Class I, Zone 2, Group IIC | |
| Air clearances and creepage distances | |
| Standards/regulations | EN 60664-1 |
| Mounting type | DIN rail mounting |
| Assembly note | No end clamp |
| Mounting position | vertical, horizontal |