View larger
UM-2KS50/32IM/SI/BFI/YCS 2908402 PHOENIX CONTACT Passive module
UM-2KS50/32IM/SI/BFI/YCS
2908402
PHOENIX CONTACT
1 Pcs.
Automation > Interface module
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact UM-2KS50/32IM/SI/BFI/YCS 2908402 PHOENIX CONTACT Passive module functions as a signal adaptation unit designed to integrate distributed control system hardware with specific automation controller cards seamlessly. Such passive modules assist in organizing signal paths while protecting sensitive automation hardware from wiring anomalies.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product type: Interface module
- Operating mode: 100% operating factor
- Data management status Article revision: 03
- Insulation characteristics Insulation: Functional insulation
- Overvoltage category: II
- Pollution degree: 2
- Nominal voltage U N: 24 V DC
- Max. current carrying capacity per branch: 250 mA (observe derating)
- Max. total current of all branches: 2 A (observe derating)
- Rated insulation voltage: 50 V DC
- Rated surge voltage: 0.5 kV
- Supported controller YOKOGAWA CENTUM VP Suitable I/O card: ADV151
- Contact switching type: 1 N/O contact
- Type of switch contact: Double contact
- Contact material: AgNi, 5 µm hard gold-plated
- Maximum switching voltage: < 25 V AC
More info
▲| Product type | Interface module |
| Operating mode | 100% operating factor |
| Data management status | |
| Article revision | 03 |
| Insulation characteristics | |
| Insulation | Functional insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
| Nominal voltage UN | 24 V DC |
| 19.2 V DC ... 26.4 V DC | |
| Max. current carrying capacity per branch | 250 mA (observe derating) |
| Max. total current of all branches | 2 A (observe derating) |
| Rated insulation voltage | 50 V DC |
| Rated surge voltage | 0.5 kV |
| Supported controller YOKOGAWA CENTUM VP | |
| Suitable I/O card | ADV151 |
| ADV161 | |
| NFDV151 | |
| NFDV161 | |
| Contact switching type | 1 N/O contact |
| Type of switch contact | Double contact |
| Contact material | AgNi, 5 µm hard gold-plated |
| Maximum switching voltage | < 25 V AC |
| 48 V DC | |
| Limiting continuous current | 1 A |
| Min. switching current | 1 mA |
| Interrupting rating (ohmic load) max. | 24 W (24 V DC) |
| 48 W (48 V DC) | |
| 25 VA (25 V AC) | |
| Mechanical service life | approx. 2x 107cycles |
| Field level | |
| Connection method | Screw connection |
| Stripping length | 5 mm |
| Screw thread | M2 |
| Number of connections | 32 |
| Number of positions | 2 |
| Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1 mm² (without ferrule) |
| Conductor cross section AWG | 26 ... 16 |
| Tightening torque | 0.22 Nm ... 0.25 Nm |
| Controller level | |
| Connection method | Yokogawa KS-compatible |
| Number of connections | 2 |
| Number of positions | 50 |
| Status display | LED (red) |
| Status display present | Yes, if the fuse fails |
| Operating voltage display | Green LED |
| Item dimensions | |
| Width | 135 mm |
| Height | 127.79 mm |
| Depth | 61.82 mm |
| Ambient conditions | |
| Degree of protection | IP00 |
| Ambient temperature (operation) | -20 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Standards/regulations | EN IEC 60664-1 |
| Mounting type | DIN rail mounting |
| Assembly note | in rows with zero spacing |
| Mounting position | any |
| Notes on operation | Do not connect adjacent channels to SELV/ PELV and voltages dangerous to the touch. |
| Notes on operation | No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC). |
| Notes on operation | Against adjacent modules in the support rail direction at least one functional insulation on the output-side is complied with. If the application has higher requirements on the insulation (basic insulation or reinforced insulation), then these must be realized through suitable measures (e. g. partition plates). |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |