PHOENIX CONTACT UKK 5-HESILED 60 (5X20) UKK 5-HESILED 60 (5X20) 0711580 PHOENIX CONTACT Fuse modular terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details

UKK 5-HESILED 60 (5X20) 0711580 PHOENIX CONTACT Fuse modular terminal block

UKK 5-HESILED 60 (5X20)

0711580

PHOENIX CONTACT

50 Pcs.

Fuse modular terminal block Fuse terminal block, fuse type: Glass/ceramic/..., fuse type: G/5 x 20, nominal voltage: 400 V, nominal current: 32 A, connection type: Screw connection, Sizing cross-section: 1.5 mm², cross-section: 0.2 mm²- 4 mm², mounting class: NS 35/7.5, NS 35/15, NS 32, colour: black Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 400 V, nominal current: 32 A, connection method: Screw connection, Rated cross section: 1.5 mm2, cross section:  0.2 mm2- 4 mm2, mounting type: NS 35/7,5, NS 35/15, NS 32, color: black

Automation > Fuse terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A UKK 5-HESILED 60 (5X20) 0711580 PHOENIX CONTACT Fuse modular terminal block serves as a dual-function electrical connector that distributes current and protects specific control loops with an integrated fuse element. Commonly implemented in industrial automation distribution panels, such blocks offer space-saving multi-tier connections alongside visual blown-fuse indication for efficient troubleshooting. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Fuse terminal block
  • Number of connections: 4
  • Number of rows: 2
  • Data management status Article revision: 06
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3
  • Fuse type: Glass / ceramics / ...
  • Rated surge voltage: 6 kV
  • Maximum power dissipation for nominal condition: 1.02 W
  • Fuse: G / 5 x 20
  • Number of connections per level: 2
  • Nominal cross section: 4 mm²
  • Level 1 above 1 below 1 Screw thread: M3
  • Tightening torque: 0.5 ... 0.8 Nm
  • Stripping length: 8 mm
  • Internal cylindrical gage: A4

More info

▲
Technical data

Product properties
Product typeFuse terminal block
Number of connections4
Number of rows2
Data management status
Article revision06
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Fuse typeGlass / ceramics / ...
Rated surge voltage6 kV
Maximum power dissipation for nominal condition1.02 W
FuseG / 5 x 20

Connection data
Number of connections per level2
Nominal cross section4 mm²
Level 1 above 1 below 1
Screw threadM3
Tightening torque0.5 ... 0.8 Nm
Stripping length8 mm
Internal cylindrical gageA4
Connection in acc. with standardIEC / EN
Conductor cross section rigid0.2 mm² ... 4 mm²
Cross section AWG24 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.2 mm² ... 4 mm²
Conductor cross section, flexible [AWG]24 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 4 mm²
2 conductors with same cross section, solid0.2 mm² ... 1.5 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1.5 mm²
Nominal current32 A
Maximum load current32 A
Nominal voltage400 V
Nominal cross section1.5 mm²

Dimensions
Width8.2 mm
Height86.5 mm
Depth on NS 3284 mm
Depth on NS 35/7,579 mm
Depth on NS 35/1586.5 mm

Material specifications
Colorblack (RAL 9005)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Mechanical properties
Mechanical data
Open side panelNo

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC / EN

Mounting
Mounting typeNS 35/7,5
NS 35/15
NS 32

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.