View larger
UCS SW 87-H 7035 2203361 PHOENIX CONTACT Side panel
UCS SW 87-H 7035
2203361
PHOENIX CONTACT
20 Pcs.
Automation > Extruded profile modular housing
Housing (HS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact UCS SW 87-H 7035 side panel is a structural element used to enclose modular electronic control equipment housings and protect interior printed circuit boards. Side panels complete custom enclosure assemblies, preventing physical damage and dust ingress within machinery control cabinets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of enclosure (EF003086): Open
- Housing connectable (EF003088): No
- Suitable for rail mounting (EF003972): No
- Wall mounting possible (EF003973): No
- With integrated PCB-mounting connection system (EF003087): No
- Colour (EF000007): Grey
- RAL-number (EF000116): 7035
- Width (EF000008): 58 mm
- Height (EF000040): 59.4 mm
- Depth (EF000049): 2 mm
More info
▲Key Commercial Data
| Orderkey | 2203361 |
|---|---|
| Packing unit | 20 pc |
| GTIN | 4055626427362 |
| Weight per Piece (excluding packing) | 8.000 g |
| Custom tariff number | 85389099 |
| Country of origin | DE (Germany) |
Material specifications
| Color (RAL) | light gray (7035) |
|---|---|
| Insulating material | PC |
| CTI according to IEC 60112 | 2 |
| Flammability rating according to UL 94 | V0 |
| Housing material | PC |
Ambient conditions
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
|---|---|
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C ... 100 °C (depending on power dissipation) |
Mechanical strength/tumbling barrel
| Specification | IEC 60068-2-31:2008-05 |
|---|---|
| Height of fall | 50 cm |
| Number of drop cycles | 50 |
Thermostability (ball thrust test)
| Specification | IEC 60695-10-2:2014-02 |
|---|---|
| Temperature | 125 °C |
| Test duration | 1 h |
| Force | 20 N |
Test for assessing the risk of fire (glow wire)
| Specification | DIN EN 60695-2-11 (VDE 0471-2-11):2014-11 |
|---|---|
| Temperature | 850 °C |
| Time of exposure | 30 s |
Test for substances that would hinder coating with paint or varnish
| Result | Test passed |
|---|---|
| Specification | VW PV 3.10.7:2005-02 |