The UCS SW 125-H 7035 side panel by Phoenix Contact is an enclosure component utilized to enclose and seal modular electronic housing assemblies used in industrial automation and control panels. Side panels provide structural integrity and environmental shielding for custom PCB layouts and embedded systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of enclosure (EF003086): Open
- Housing connectable (EF003088): No
- Suitable for rail mounting (EF003972): No
- Wall mounting possible (EF003973): No
- With integrated PCB-mounting connection system (EF003087): No
- Colour (EF000007): Grey
- RAL-number (EF000116): 7035
- Width (EF000008): 96 mm
- Height (EF000040): 59.4 mm
- Depth (EF000049): 2 mm
More info
▲Key Commercial Data
| Orderkey | 2203367 |
|---|---|
| Packing unit | 10 pc |
| GTIN | 4055626427386 |
| Weight per Piece (excluding packing) | 13.770 g |
| Custom tariff number | 85389099 |
| Country of origin | DE (Germany) |
Material specifications
| Color (RAL) | light gray (7035) |
|---|---|
| Insulating material | PC |
| CTI according to IEC 60112 | 2 |
| Flammability rating according to UL 94 | V0 |
| Housing material | PC |
Ambient conditions
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
|---|---|
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C ... 100 °C (depending on power dissipation) |
Mechanical strength/tumbling barrel
| Specification | IEC 60068-2-31:2008-05 |
|---|---|
| Height of fall | 50 cm |
| Number of drop cycles | 50 |
Thermostability (ball thrust test)
| Specification | IEC 60695-10-2:2014-02 |
|---|---|
| Temperature | 125 °C |
| Test duration | 1 h |
| Force | 20 N |
Test for assessing the risk of fire (glow wire)
| Specification | DIN EN 60695-2-11 (VDE 0471-2-11):2014-11 |
|---|---|
| Temperature | 850 °C |
| Time of exposure | 30 s |
Test for substances that would hinder coating with paint or varnish
| Result | Test passed |
|---|---|
| Specification | VW PV 3.10.7:2005-02 |