BLT-T2-320-UT 2906100 PHOENIX CONTACT Type 2 surge arrester
BLT-T2-320-UT
2906100
PHOENIX CONTACT
10 Pcs.
Automation > Surge protection device for power supply systems
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact produces the BLT-T2-320-UT Type 2 surge arrester to protect electrical distribution networks from transient overvoltage events and lightning currents. Such modular arresters are typically integrated into TT system configurations to protect internal wiring and connected machinery. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- System configuration DC (EF009926): No
- System configuration IT (EF009927): No
- System configuration TN (EF009928): No
- System configuration TN-C (EF009929): No
- System configuration TN-C-S (EF009933): No
- System configuration TN-S (EF009930): No
- System configuration TT (EF009931): Yes
- System configuration other (EF009932): No
- Nominal discharge surge current (8/20) (EF004214): 5 kA
- Max. discharge surge current (8/20) (EF012274): 10 kA
- Max. continuous voltage AC (EF004198): 320 V
- Voltage protection level L-N (EF004236): 1.3 kV
- Short-circuit breaking capacity (Isccr) (EF012627): 3 kA
- Integrated backup fuse (EF008797): Yes
- Leakage-current free (EF016002): No
- Signalling at the device (EF004241): Optic
More info
▲Key Commercial Data
| Orderkey | 2906100 |
|---|---|
| Packing unit | 10 pc |
| Minimum order quantity | 10 pc |
| Catalog page | Page 69 (C-4-2017) |
| GTIN | 4055626058078 |
| Weight per Piece (excluding packing) | 39.000 g |
| Custom tariff number | 85363030 |
| Country of origin | CN (China) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
General
| IEC test classification | II / III |
|---|---|
| T2 / T3 | |
| EN type | T2 / T3 |
| IEC power supply system | TT |
| TN-C | |
| IT | |
| Mode of protection | L-N |
| Mounting type | 4 mm screw |
| Color | light grey RAL 7035 |
| Housing material | PA 6.6 |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Protection class | II |
| Type | Installation module |
| Surge protection fault message | optical |
Protective circuit
| Nominal voltage UN | 100 V AC ... 277 V AC |
|---|---|
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous voltage UC | 320 V AC |
| Rated load current IL | 16 A |
| Nominal discharge current In(8/20) µs | 5 kA |
| Maximum discharge current Imax(8/20) µs | 10 kA |
| Combination wave UOC | 10 kV |
| Short-circuit current rating ISCCR | 3 kA |
| Voltage protection level Up | ≤ 1.3 kV |
| Residual voltage Ures | ≤ 1.3 kV (at In) |
| ≤ 1.3 kV (at UOC) | |
| TOV behavior at UT | 400 V AC (5 s / withstand mode) |
| 528 V AC (120 min / safe failure mode) | |
| Response time tA | ≤ 25 ns |
| Max. backup fuse with V-type through wiring | 16 A (MCB B/C) |
| Max. backup fuse with branch wiring | 16 A (MCB B/C) |
| Combination wave UOC | 10 kV |
Connection data
| Connection method | Screw terminal blocks |
|---|---|
| Screw thread | M3 |
| Tightening torque | 0.6 Nm |
| 2 conductors with same cross section, stranded min. | 0.2 mm² |
| 2 conductors with same cross section, stranded max. | 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| 2 conductors with same cross section, solid min. | 0.2 mm² |
| 2 conductors with same cross section, solid max. | 1.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |