PHOENIX CONTACT RIF-1-RPT-LDP-24DC/1IC RIF-1-RPT-LDP-24DC/1IC 2909884 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

RIF-1-RPT-LDP-24DC/1IC 2909884 PHOENIX CONTACT Relay Module

RIF-1-RPT-LDP-24DC/1IC

2909884

PHOENIX CONTACT

10 Pcs.

Relay Module Pre-assembled relay module with push-in connection consisting of: relay socket, relay with power contact, plug-in indication/antiparasitic module and clamping flange. Contact version: 1 normally open contact, max. shut-off current up to 130 A peak, 80 A (20 ms) input voltage 24 V DC Preassembled relay module with Push-in connection, consisting of: relay base, power contact relay, plug-in display/interference suppression module, retaining bracket. Contact switching type: 1 N/O contact, max. inrush current up to 130 A peak, 80 A (20 ms), 24 V DC input voltage

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact RIF-1-RPT-LDP-24DC/1IC relay module is engineered to handle demanding electrical loads, providing safe switching isolation in industrial power distribution setups. Specialized modules of this type protect downstream equipment by reliably managing severe power spikes and operational currents.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Relay Module
  • Product family: RIFLINE complete
  • Application: high inrush currents
  • Operating mode: 100% operating factor
  • Mechanical service life: 3x 10 7 cycles
  • Data management status Date of last data management: 15.10.2024
  • Article revision: 05
  • Insulation characteristics: Standards/regulations Insulation: Safe isolation, reinforced insulation
  • Overvoltage category: III
  • Pollution degree: 2
  • Maximum power dissipation for nominal condition: 0.43 W
  • Test voltage (Winding/contact): 4 kV AC (50 Hz, 1 min., winding/contact)
  • Standards/regulations Rated insulation voltage: 250 V AC
  • Rated surge voltage: 6 kV
  • Coil side Nominal input voltage U N: 24 V DC
  • Input voltage range: 19.2 V DC ... 33.6 V DC (20 °C)

More info

▲
Technical data

Notes
Notes on operationFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)

Product properties
Product typeRelay Module
Product familyRIFLINE complete
Applicationhigh inrush currents
Operating mode100% operating factor
Mechanical service life3x 107cycles
Data management status
Date of last data management15.10.2024
Article revision05
Insulation characteristics: Standards/regulations
InsulationSafe isolation, reinforced insulation
Overvoltage categoryIII
Pollution degree2

Electrical properties
Maximum power dissipation for nominal condition0.43 W
Test voltage (Winding/contact)4 kV AC (50 Hz, 1 min., winding/contact)
Standards/regulations
Rated insulation voltage250 V AC
Rated surge voltage6 kV

Input data
Coil side
Nominal input voltage UN24 V DC
Input voltage range19.2 V DC ... 33.6 V DC (20 °C)
Input voltage range in reference to UNsee diagram
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN18 mA
Typical response time8 ms
Typical release time10 ms
Coil voltage24 V DC
Protective circuitFreewheeling diode; Freewheeling diode
Operating voltage displayYellow LED

Output data
Switching
Contact switching type1 N/O contact
Type of switch contactSingle contact
Contact materialAgSnO
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage12 V (100 mA)
Limiting continuous current6 A
10 A (Value is permissible if connections 11 and 21, as well as connections 14 and 24 are bridged.)
Maximum inrush current80 A (20 ms)
130 A (peak, at capacitive load, 230 V AC, 24 μF)
Min. switching current100 mA (12 V DC)
Interrupting rating (ohmic load) max.264 W (at 24 V DC, observe contact derating)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
2750 VA (at 250 V AC, observe contact derating)
Switching capacity min.1200 mW
Utilization category CB Scheme (IEC 60947-5-1)AC15, 6 A/250 V (N/O contact)
DC13, 2 A/24 V (N/O contact)

Connection data
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
26 ... 16 (flexible)

Dimensions
Drill hole
Diameter3.2 mm
Width16 mm
Height96 mm
Depth75 mm

Material specifications
Colorgray (RAL 7042)

Environmental and real-life conditions
Ambient conditions
Degree of protection (Relay base)IP20 (Relay base)
Degree of protection (Relay)RT III (Relay)
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m

Approvals
Corrosive gas test
IdentificationISA-S71.04. G3 Harsh Group
EN 60068-2-60

Standards and regulations
Standards/regulations
Standards/regulationsIEC 60947-5-1

Mounting
Mounting typeDIN rail mounting
Assembly notein rows with zero spacing
Mounting positionany

Product Datasheet