View larger
TTC-6P-2X1-M-EX-24DC-UT-I 2906825 PHOENIX CONTACT Surge protection, consisting of protective plug and base e..
TTC-6P-2X1-M-EX-24DC-UT-I
2906825
PHOENIX CONTACT
1 Pcs.
Automation > Combined arrester for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A surge protection device combines a protective plug and base element to safeguard instrumentation and control loops against transient overvoltages in hazardous or standard industrial environments. The Phoenix Contact TTC-6P-2X1-M-EX-24DC-UT-I offers reliable signal line protection while maintaining compact dimensions on standard DIN rails.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2906825
- Packing unit: 1 pc
- Catalog page: Page 157 (C-4-2019)
- GTIN: 40556135878
- Weight per Piece (excluding packing): 40.000 g
- Custom tariff number: 85363010
- Country of origin: DE (Germany)
- Height: 105.8 mm
- Width: 6.2 mm +0.1 mm
- Depth: 100 mm (incl. DIN rail 7.5 mm)
- Ambient temperature (operation): -40 °C ... 85 °C
- Ambient temperature (storage/transport): -40 °C ... 85 °C
- Permissible humidity (operation): 5 % ... 95 %
- Altitude: ≤ 2000 m (amsl (above mean sea level))
- Degree of protection: IP20
- Housing material: PBT
More info
▲Key Commercial Data
| Orderkey | 2906825 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 157 (C-4-2019) |
| GTIN | 4055626135878 |
| Weight per Piece (excluding packing) | 40.000 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 85 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Degree of protection | IP20 |
General
| Housing material | PBT |
|---|---|
| Flammability rating according to UL 94 | V-0 |
| Color | sky blue RAL 5015 |
| Mounting type | DIN rail: TH 35 - 7.5 mm |
| Type | DIN rail module, two-section, divisible |
| Direction of action | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
Protective circuit
| IEC test classification | C1 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| Nominal voltage UN | 24 V DC |
| Maximum continuous voltage UC | 30 V DC |
| Rated current | 600 mA (40 °C) |
| Operating effective current ICat UC | ≤ 5 µA |
| Residual current IPE | ≤ 10 µA |
| Nominal discharge current In(8/20) µs (line-earth) | 5 kA |
| Pulse discharge current Iimp(10/350) µs (line-earth) | 0.5 kA |
| Total discharge current Itotal(8/20) µs | 10 kA |
| Voltage protection level Up(line-earth) | ≤ 140 V (C1 - 1 kV/500 A) |
| ≤ 190 V (C2 - 10 kV / 5 kA) | |
| ≤ 50 V (C3 - 100 A) | |
| Voltage protection level Upstatic (line-earth) | ≤ 55 V (C1 - 1 kV/500 A) |
| ≤ 120 V (C2 - 10 kV / 5 kA) | |
| Response time tA(line-earth) | ≤ 1 ns |
| Input attenuation aE, asym. | typ. 0.3 dB (≤ 270 kHz/150 Ω) |
| Cut-off frequency fg (3 dB), asym. (PE) in 150 Ohm system | typ. 960 kHz |
| Capacity (line-earth) | typ. 2.2 nF |
| Resistance per path | 1.65 Ω ±20 % |
| Surge protection fault message | optical |
| Max. required back-up fuse | 630 mA (FF) |
| Impulse durability (line-earth) | C1 - 1 kV / 500 A |
| C2 - 10 kV / 5 kA | |
| C3 - 100 A | |
| D1 - 500 A | |
| Pulse reset time (line-earth) | ≤ 300 ms |
Connection data
| Connection method | Screw connection |
|---|---|
| Screw thread | M3 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Stripping length | 8 mm |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
Standards and Regulations
| Standards/specifications | EN 60079-0 2012 + A11:2013 |
|---|---|
| EN 60079-11 2012 | |
| EN 61643-21 2001 + A1:2009 + A2:2013 | |
| IEC 60079-0 2011 (modified) + corrigendum 2012 + corrigendum 2013 | |
| IEC 60079-11 2008 | |
| IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 |
General
| Maximum inner capacitance Ci | negligible |
|---|---|
| Max. internal inductance Li | negligible |
| Max. input current Ii | 400 mA (T4 / ≤ 50 °C) |
| 350 mA (T6 / ≤ 35 °C) | |
| Max. input voltage Ui | 30 V DC |
| Ambient temperature (operation) | -40 °C ... 35 °C (T6 / 85 °C) |
| -40 °C ... 50 °C (T4 / 135 °C) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Classifications
eCl@ss
| eCl@ss 4.0 | 27140201 |
|---|---|
| eCl@ss 4.1 | 27130801 |
| eCl@ss 5.0 | 27130801 |
| eCl@ss 5.1 | 27130801 |
| eCl@ss 6.0 | 27130800 |
| eCl@ss 7.0 | 27130807 |
| eCl@ss 8.0 | 27130807 |
| eCl@ss 9.0 | 27130807 |
UNSPSC
| UNSPSC 6.01 | 30212010 |
|---|---|
| UNSPSC 7.0901 | 39121610 |
| UNSPSC 11 | 39121610 |
| UNSPSC 12.01 | 39121610 |
| UNSPSC 13.2 | 39121620 |
| UNSPSC 18.0 | 39121620 |
| UNSPSC 19.0 | 39121620 |
| UNSPSC 20.0 | 39121620 |
| UNSPSC 21.0 | 39121620 |