PHOENIX CONTACT TTC-6P-1X2-EX-24DC-UT-I TTC-6P-1X2-EX-24DC-UT-I 1065312 PHOENIX CONTACT Surge protection, consisting of protective plug and base ele.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

TTC-6P-1X2-EX-24DC-UT-I 1065312 PHOENIX CONTACT Surge protection, consisting of protective plug and base ele..

TTC-6P-1X2-EX-24DC-UT-I

1065312

PHOENIX CONTACT

1 Pcs.

Surge protection, consisting of protective plug and base element, with integrated status indicator for a 2-wire floating Ex i signal circuit, e.g. 0(4) - 20 mA current loop. Surge protection, consisting of plug-in protection and base element, with integrated status indication for a potential-free 2-wire intrinsically safe signal circuit, e.g. 0(4) current loop... 20 mA, suitable for HART. Surge protection, consisting of protective plug and base element, with integrated status indicator for a 2-wire floating Ex i signal circuit, e.g., 0(4) mA … 20 mA current loop, HART-compatible. Can be used in safety-related circuits up to SIL 3.

Automation > Combined arrester for data networks/MCR-technology
Trabtech (TT)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The TTC-6P-1X2-EX-24DC-UT-I 1065312 PHOENIX CONTACT Surge protection, consisting of protective plug and base ele.. created by Phoenix Contact is a complete surge protection assembly featuring a plug and base element configuration. Technicians use these modular units to shield low-voltage measurement and control circuits from transient overvoltages. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Surge protection for MCR technology
  • Product family: TERMITRAB complete
  • IEC test classification: C1
  • Type: DIN rail module, two-section, divisible
  • Wire pairs per module: 1
  • Data management status Article revision: 10
  • Insulation characteristics Overvoltage category: III
  • Pollution degree: 2
  • Nominal voltage U N: 24 V DC
  • Connection method: Screw connection
  • Screw thread: M3
  • Tightening torque: 0.5 Nm ... 0.6 Nm
  • Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
  • Conductor cross section rigid: 0.2 mm² ... 4 mm²
  • Conductor cross section AWG: 24 ... 12
  • Maximum inner capacitance C i: negligible

More info

▲
Technical data

Product properties
Product typeSurge protection for MCR technology
Product familyTERMITRAB complete
IEC test classificationC1
C2
C3
D1
TypeDIN rail module, two-section, divisible
Wire pairs per module1
Data management status
Article revision10
Insulation characteristics
Overvoltage categoryIII
Pollution degree2

Electrical properties
Nominal voltage UN24 V DC

Connection data
Connection methodScrew connection
Screw threadM3
Tightening torque0.5 Nm ... 0.6 Nm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12

Ex data
Maximum inner capacitance Cinegligible
Max. internal inductance Linegligible
Max. input current Ii400 mA (T4 / -40 °C ... +50 °C)
250 mA (T4 / -40 °C ... +70 °C)
350 mA (T6 / -40 °C ... +35 °C)
100 mA (T6 / -40 °C ... +70 °C)
Max. input voltage Ui30 V DC
Insulation voltage to ground> 180 V DC
Ambient temperature (operation)-40 °C ... 70 °C (with current derating)

Dimensions
Dimensional drawing
Width6.2 mm +0.1 mm
Height105.8 mm
Depth100 mm (incl. DIN rail 7.5 mm)

Material specifications
Colorblue (RAL 5015)
light gray (RAL 7035)
Flammability rating according to UL 94V-0
Insulating materialPBT
Housing materialPBT

Mechanical properties
Mechanical data
Open side panelNo

Protective circuit
Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC30 V DC
Rated current600 mA (40 °C)
Operating effective current ICat UC≤ 5 µA
Residual current IPE≤ 1 µA
Nominal discharge current In(8/20) µs (line-line)5 kA
Nominal discharge current In(8/20) µs (line-ground)5 kA
Pulse discharge current Iimp(10/350) µs (line-line)0.5 kA
Pulse discharge current Iimp(10/350) µs (line-earth)0.5 kA
Total discharge current Itotal(8/20) µs10 kA
Voltage protection level Up(line-line)≤ 55 V (C1 - 1 kV / 500 A)
≤ 65 V (C2 - 10 kV / 5 kA)
≤ 55 V (C3 - 100 A)
Voltage protection level Up(line-earth)≤ 900 V (C1 - 1 kV / 500 A)
≤ 1.05 kV (C2 - 10 kV / 5 kA)
≤ 1.4 kV (C3 - 100 A)
Voltage protection level Upstatic (line-line)≤ 50 V (C1 - 1 kV / 500 A)
≤ 65 V (C2 - 10 kV / 5 kA)
Voltage protection level Upstatic (line-earth)≤ 900 V (C1 - 1 kV / 500 A)
≤ 1.05 kV (C2 - 10 kV / 5 kA)
Response time tA(line-line)≤ 1 ns
Response time tA(line-earth)≤ 100 ns
Input attenuation aE, sym.typ. 0.3 dB (≤ 250 kHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 940 kHz
Capacity (Core-Core)typ. 2 nF
Resistance per path1.65 Ω ±20 %
Surge protection fault messageoptical
Max. required back-up fuse630 mA (FF)
Impulse durability (line-line)C1 - 1 kV / 500 A
C2 - 10 kV / 5 kA
C3 - 100 A
Impulse durability (line-earth)C1 - 1 kV / 500 A
C2 - 10 kV / 5 kA
C3 - 100 A
D1 - 500 A
Pulse reset time (line-line)≤ 700 ms
Pulse reset time (line-earth)≤ 30 ms

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %

Approvals
Conformity/Approvals
UL, USA / CanadaClass I, Div. 2, Groups A, B, C, D T4A

Standards and regulations
Standards/specificationsEN 60079-0
Note2018
Standards/specificationsEN 60079-11
Note2012
EN 61643-21
Standards/specificationsEN 61643-21
Note2001 + A1:2009 + A2:2013
Standards/specificationsIEC 60079-0
Note2017
Standards/specificationsIEC 60079-11
Note2008
Standards/specificationsIEC 61643-21
Note2000 + corrigendum 2001 + A1:2008, modified + A2:2012

Mounting
Mounting typeDIN rail: TH 35 - 7.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.