View larger
TRIO2-DIODE/12-24DC/2X10/1X20 2907380 PHOENIX CONTACT Diode
TRIO2-DIODE/12-24DC/2X10/1X20
2907380
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection module
Power Supplies (PS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact TRIO2-DIODE/12-24DC/2X10/1X20 diode module provides redundant decoupling for power supply units in industrial automation systems. Redundancy modules are widely used to isolate parallel power paths, ensuring continuous operation if one power supply fails. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- DC operation Nominal input voltage range: 12 V DC ... 24 V DC
- Input voltage range: 10 V DC ... 30 V DC
- Voltage type of supply voltage: DC
- Reverse polarity protection: < yes60 V
- Nominal input current (I N ): 2x 10 A (-25 °C ... 60 °C)
- Maximum current I max: 2x 15 A (-25 °C ... 40 °C)
- Transient surge protection: Varistor
- Voltage drop, input/output: 0.5 V
- Efficiency: > 97 %
- Nominal output voltage: U In - 0,5 V
- Nominal output current (I N ): 20 A
- Derating: 60 °C ... 70 °C (2.5 %/K)
- Power loss nominal load max.: 5 W (I OUT = 10 A)
- Connection in series: no
More info
▲| DC operation | |
| Nominal input voltage range | 12 V DC ... 24 V DC |
| Input voltage range | 10 V DC ... 30 V DC |
| Voltage type of supply voltage | DC |
| Reverse polarity protection | < yes60 V |
| Nominal input current (IN) | 2x 10 A (-25 °C ... 60 °C) |
| 1x 20 A (-25 °C ... 60 °C) | |
| Maximum current Imax | 2x 15 A (-25 °C ... 40 °C) |
| 1x 30 A (-25 °C ... 40 °C) | |
| Nominal input current (IN) | 2x 10 A (-25 °C ... 60 °C) |
| 1x 20 A (-25 °C ... 60 °C) | |
| Transient surge protection | Varistor |
| Voltage drop, input/output | 0.5 V |
| Efficiency | > 97 % |
| Nominal output voltage | UIn- 0,5 V |
| Nominal output current (IN) | 20 A |
| 10 A | |
| Derating | 60 °C ... 70 °C (2.5 %/K) |
| Power loss nominal load max. | 5 W (IOUT= 10 A) |
| Connection in series | no |
| Derating | 60 °C ... 70 °C (2.5 %/K) |
| Input | |
| Connection method | Push-in connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 4 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 16 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 10 mm |
| Output | |
| Connection method | Screw connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 10 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 6 mm² |
| Conductor cross section AWG min. | 12 |
| Conductor cross section AWG max. | 8 |
| Stripping length | 15 mm |
| Screw thread | M3 |
| Tightening torque, min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
| Insulation voltage input, output / housing | 500 V |
| Product type | Redundancy module |
| Product family | TRIO DIODE |
| MTBF (IEC 61709, SN 29500) | 66425178 h (25 °C) |
| 56586762 h (40 °C) | |
| 41744164 h (60 °C) | |
| LED | no |
| Data management status | |
| Article revision | 04 |
| Insulation characteristics | |
| Protection class | III |
| Degree of pollution | 2 |
| Width | 35 mm |
| Height | 130 mm |
| Depth | 115 mm |
| Installation dimensions | |
| Installation distance right/left | 0 mm / 0 mm |
| Installation distance top/bottom | 50 mm / 50 mm |
| Mounting type | DIN rail mounting |
| Assembly note | alignable: horizontally 0 mm, vertically 50 mm |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
| Housing material | Metal |
| Type of housing | Steel sheet, zinc-plated |
| Side element version | Aluminum |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| 15 Hz ... 150 Hz, 2.3g, 90 min. | |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
| Standard - Electrical safety | IEC 62368-1 (SELV) |
| Standard – Safety extra-low voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) |
| UL approvals | UL/C-UL listed UL 508 |
| UL/C-UL Recognized UL 60950-1 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| EMC requirements for noise emission | EN 61000-6-3 |
| EN 61000-6-4 | |
| EMC requirements for noise immunity | EN 61000-6-1 |
| EN 61000-6-2 | |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electrostatic discharge | |
| Contact discharge | 4 kV (Test Level 3) |
| Discharge in air | 8 kV (Test Level 3) |
| Comments | Criterion B |
| Electromagnetic HF field | |
| Standards/regulations | EN 61000-4-3 |
| Electromagnetic HF field | |
| Frequency range | 80 MHz ... 1 GHz |
| Test field strength | 10 V/m |
| Frequency range | 1 GHz ... 2 GHz |
| Test field strength | 10 V/m |
| Frequency range | 2 GHz ... 3 GHz |
| Test field strength | 10 V/m |
| Comments | Criterion A |
| Fast transients (burst) | |
| Standards/regulations | EN 61000-4-4 |
| Fast transients (burst) | |
| Input | 2 kV (Test Level 3 - asymmetrical) |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Comments | Criterion B |
| Surge voltage load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Surge voltage load (surge) | |
| Input | 0.5 kV (Test Level 2 - symmetrical) |
| 0.5 kV (Test Level 3 - asymmetrical) | |
| Output | 0.5 kV (Test Level 1 - symmetrical) |
| 0.5 kV (Test Level 1 - asymmetrical) | |
| Comments | Criterion B |
| Conducted interference | |
| Standards/regulations | EN 61000-4-6 |
| Conducted interference | |
| I/O/S | asymmetrical |
| Frequency range | 0.15 MHz ... 80 MHz |
| Comments | Criterion A |
| Voltage | 10 V (Test Level 3) |
| Voltage dips | |
| Standards/regulations | EN 61000-4-11 |
| Emitted interference | |
| Standards/regulations | EN 61000-6-3 |
| Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Criteria | |
| Criterion A | Normal operating behavior within the specified limits. |