Request QuoteProduct Overview
Guaranteed power continuity for delicate control systems is achieved with the Phoenix Contact TRIO-UPS-2G/1AC/24DC/20 uninterruptible power supply. This device maintains steady DC voltage levels and buffers against electrical grid failures to prevent automation shutdown.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage range: 100 V AC ... 240 V AC -15 % ... +10 %
- Voltage type of supply voltage: AC
- Inrush current: < 10 A
- Inrush current integral (I 2 t): < 0.4 A 2 s
- Frequency range (f N ): 50 Hz ... 60 Hz (±10 %)
- Mains buffering time: ≥ 20 ms (120 V AC)
- Switch-on time: typ. 200 ms
- Typical current consumption: 6.4 A (100 V AC)
- Input fuse: 10 A (slow-blow, internal)
- Signal Bat.-Start Connection labeling: 3.6
- Signalization designation: Bat.-Start
- Low signal: Connection to SGnd with < 2.7 kΩ
- High signal: Open (> 200 kΩ between Bat.-Start and SGnd)
- Signal Remote Connection labeling: 3.5
- Signalization designation: Remote
- Low signal: Connection to SGnd with < 2.7 kΩ
More info
▲| Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
| Voltage type of supply voltage | AC |
| Inrush current | < 10 A |
| Inrush current integral (I2t) | < 0.4 A2s |
| Frequency range (fN) | 50 Hz ... 60 Hz (±10 %) |
| Mains buffering time | ≥ 20 ms (120 V AC) |
| Switch-on time | typ. 200 ms |
| Typical current consumption | 6.4 A (100 V AC) |
| Input fuse | 10 A (slow-blow, internal) |
| Signal Bat.-Start | |
| Connection labeling | 3.6 |
| Signalization designation | Bat.-Start |
| Low signal | Connection to SGnd with < 2.7 kΩ |
| High signal | Open (> 200 kΩ between Bat.-Start and SGnd) |
| Signal Remote | |
| Connection labeling | 3.5 |
| Signalization designation | Remote |
| Low signal | Connection to SGnd with < 2.7 kΩ |
| High signal | Open (> 35 kΩ between Remote and SGnd) |
| Efficiency | typ. 88 % (100 V AC) |
| typ. 92 % (240 V AC) | |
| typ. (Battery operation) | |
| Derating | > 60 °C (2.5%/K of POutnom.) |
| Crest factor | 1.57 (120 V AC) |
| 1.58 (230 V AC) | |
| Switch-over time | < 3 ms |
| UPS connection in parallel | yes, with diode module uncoupled |
| UPS connection in series | no |
| Energy storage device connection in parallel | yes |
| Feedback voltage resistance | ≤ 35 V DC |
| Protection against overvoltage at the output (OVP) | < 30 V DC |
| Residual ripple | < 20 mV |
| Control deviation | < 0.4 % (change in load, static 10 % ... 90 %) |
| < 2.9 % (Dynamic load change 10 % ... 90 %, 10 Hz) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Rise time | < 34 ms |
| Permissible backup fuse | B16 |
| Mains operation | |
| Output voltage | 24 V DC |
| Output voltage range | 24 V DC ... 28 V DC (> 24 V constant capacity) |
| Output current IN | 20 A |
| Dynamic Boost (IDyn.Boost) | 30 A |
| Maximum no-load power dissipation | < 4 W (230 V AC) |
| Power loss nominal load max. | < 50 W (230 V AC) |
| Battery operation | |
| Output voltage | UBAT-0.1 V DC |
| Output voltage range | 18 V DC ... 30 V DC |
| Output current IN | 20 A |
| Signal Alarm | |
| Connection labeling | 3.2 |
| Signalization designation | Alarm |
| Type of signaling | LED red |
| Switching output | Transistor output, active |
| Output voltage | 24 V DC |
| Continuous load current | 20 mA |
| LED status indicator | red |
| Signal Battery mode | |
| Connection labeling | 3.3 |
| Signalization designation | Battery mode |
| Type of signaling | Yellow LED |
| Switching output | Transistor output, active |
| Output voltage | 24 V DC |
| Continuous load current | 20 mA |
| LED status indicator | yellow |
| Signal DC OK | |
| Connection labeling | 3.1 |
| Signalization designation | DC OK |
| Type of signaling | Green LED |
| Switching output | Transistor output, active |
| Output voltage | 24 V DC |
| Continuous load current | 20 mA |
| LED status indicator | green |
| Signal Ready | |
| Connection labeling | 3.4 |
| Signalization designation | Ready |
| Switching output | Transistor output, active |
| Output voltage | 24 V DC |
| Continuous load current | 20 mA |
| Nominal voltage UN | 24 V DC |
| End-of-charge voltage | max. 30 V DC |
| Charging current (Configurable) | 0.2 A ... 3 A (-25 °C ... 40 °C) |
| Charging current (Reduced) | 3 A ... 0 A (40 °C ... 65 °C) |
| Charging current (Preset) | 2.1 A (-25 °C ... 40 °C) |
| Charging current () | 3 A |
| Nominal capacity range | 4 Ah ... 40 Ah |
| Battery technology | VRLA-AGM |
| Charge characteristic curve | IU0U |
| Conductor connection | |
| Connection method | Push-in connection |
| rigid | 1 mm² ... 4 mm² |
| flexible | 1 mm² ... 2.5 mm² |
| flexible with ferrule without plastic sleeve | 1 mm² ... 2.5 mm² |
| flexible with ferrule with plastic sleeve | 1 mm² ... 1.5 mm² |
| rigid (AWG) | 16 ... 12 |
| Stripping length | 10 mm |
| Conductor connection | |
| Connection method | Push-in connection |
| rigid | 2.5 mm² ... 10 mm² |
| flexible | 2.5 mm² ... 6 mm² |
| flexible with ferrule without plastic sleeve | 2.5 mm² ... 6 mm² |
| flexible with ferrule with plastic sleeve | 2.5 mm² ... 4 mm² |
| rigid (AWG) | 12 ... 8 |
| Stripping length | 15 mm |
| Conductor connection | |
| Connection method | Push-in connection |
| rigid | 0.2 mm² ... 1.5 mm² |
| flexible | 0.2 mm² ... 1.5 mm² |
| flexible with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
| flexible with ferrule with plastic sleeve | 0.2 mm² ... 0.75 mm² |
| rigid (AWG) | 24 ... 16 |
| Stripping length | 8 mm |
| Conductor connection | |
| Connection method | Push-in connection |
| rigid | 2.5 mm² ... 10 mm² |
| flexible | 2.5 mm² ... 6 mm² |
| flexible with ferrule without plastic sleeve | 2.5 mm² ... 6 mm² |
| flexible with ferrule with plastic sleeve | 2.5 mm² ... 4 mm² |
| rigid (AWG) | 12 ... 8 |
| Stripping length | 15 mm |
| Interface | USB (Modbus/RTU) |
| Number of interfaces | 1 |
| Connection method | MINI-USB Type B |
| Locking | Screw |
| Number of phases | 1.00 |
| Product type | DC UPS with integrated power supply |
| Product family | TRIO UPS |
| MTBF (IEC 61709, SN 29500) | 958219 h (25 °C) |
| 576370 h (40 °C) | |
| 265724 h (60 °C) | |
| Insulation characteristics | |
| Protection class | I |
| Degree of pollution | 2 |
| Item dimensions | |
| Width | 88 mm |
| Height | 130 mm |
| Depth | 160 mm |
| Item dimensions with alternative mounting | |
| Width | 160 mm |
| Height | 130 mm |
| Depth | 88 mm |
| Installation dimensions | |
| Installation distance right/left | 0 mm / 0 mm |
| Installation distance top/bottom | 50 mm / 50 mm |
| Mounting type | DIN rail mounting |
| Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
| Hood version | PC |
| Side element version | Aluminum |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Ambient temperature (start-up type tested) | -40 °C |
| Maximum altitude | ≤ 4000 m (> 2000 m, observe derating) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (At +25°C, non-condensing) |
| Shock | 30g, 18 ms in accordance with IEC 60068-2-27 |
| Vibration (operation) | in accordance with IEC 60068-2-6 |
| Overvoltage category | |
| EN 61010-1 | II |
| Safety for measurement, control, and laboratory equipment | |
| Standard designation | Safety for equipment for measurement, control, and laboratory use |
| Standards/specifications | IEC 61010-1 |
| Protective extra-low voltage | |
| Standard designation | Protective extra-low voltage |
| Standards/specifications | IEC 61010 (SELV) / (PELV) |
| Safe isolation | |
| Standard designation | Safe isolation |
| Standards/specifications | DIN VDE 0100-410 |
| Low-voltage power supplies, DC output | |
| Standard designation | Low-voltage power supplies, DC output |
| Standards/specifications | EN 61204-3 |
| UL | |
| Identification | UL Listed UL 61010 |
| UL | |
| Identification | UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| EMC requirements for noise emission | EN 61000-6-3 |
| EN 61000-6-4 | |
| EMC requirements for noise immunity | EN 61000-6-1 |
| EN 61000-6-2 | |
| Noise immunity | Immunity in accordance with EN 61000-6-2 (industrial) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Conducted noise emission | EN 61000-6-3 |
| Noise emission | EN 61000-6-3 |
| Harmonic currents | |
| Standards/regulations | EN 61000-3-2 |
| Flicker | |
| Standards/regulations | EN 61000-3-3 |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electrostatic discharge | |
| Contact discharge | 6 kV (Test Level 3) |
| Discharge in air | 8 kV (Test Level 3) |
| Electromagnetic HF field | |
| Standards/regulations | EN 61000-4-3 |
| Electromagnetic HF field | |
| Frequency range | 80 MHz ... 6 GHz |
| Test field strength | 10 V/m |
| Frequency range | 1.4 GHz ... 6 GHz |
| Test field strength | 3 V/m |
| Fast transients (burst) | |
| Standards/regulations | EN 61000-4-4 |
| Fast transients (burst) | |
| Input | 4 kV |
| Output | 2 kV |
| Signal | 2 kV |
| Surge voltage load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Input | 2 kV (Test Level 4 - symmetrical) |
| 4 kV (Test Level 4 - asymmetrical) | |
| Output | 1 kV (Test Level 3 - symmetrical) |
| 2 kV (Test Level 3 - asymmetrical) | |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Conducted interference | |
| Standards/regulations | EN 61000-4-6 |
| Conducted interference | |
| Frequency range | 0.15 MHz ... 80 MHz |
| Voltage | 10 V |