View larger
TRIO-UPS-2G/1AC/1AC/230V/750VA 2905909 PHOENIX CONTACT Uninterruptible power supply
TRIO-UPS-2G/1AC/1AC/230V/750VA
2905909
PHOENIX CONTACT
1 Pcs.
Automation > UPS
Power Supplies (PS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact TRIO-UPS-2G/1AC/1AC/230V/750VA is an uninterruptible power supply engineered to safeguard localized automation setups against electrical disturbances. Industrial automation architectures rely on such units to maintain continuous operational readiness for sensitive controllers and instrumentation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 184 V
- Output voltage (EF003933): 230 V
- SNMP (EF005284): No
- Voltage type (EF000187): AC
- Height (EF000040): 170 mm
- Width (EF000008): 210 mm
- Depth (EF000049): 136 mm
- Weight (EF000167): 6.009 kg
- Bridging time full load (EF000428): 60 min
More info
▲Key Commercial Data
| Orderkey | 2905909 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 282 (C-4-2017) |
| GTIN | 4055626007502 |
| Weight per Piece (excluding packing) | 6,155.600 g |
| Custom tariff number | 85044030 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | 0 °C ... 40 °C |
|---|---|
| Ambient temperature (storage/transport) | -15 °C ... 40 °C (with charged energy storage device) |
| Max. permissible relative humidity (operation) | ≤ 95 % (25 °C, non-condensing) |
| Maximum altitude | ≤ 3000 mm (> 2000 m, observe derating) |
| Vibration (operation) | 5 Hz ... 100 Hz, 0.7g (EN 60068-2-6) |
| Shock | 20g in all directions (EN 60068-2-27) |
| 30g in each space direction with UWA 130 | |
| Degree of pollution | 2 |
| Climatic class | 3K3 (in acc. with EN 60721) |
Input data
| Nominal input voltage | 230 V AC |
|---|---|
| Input voltage range | 184 V AC ... 264 V AC |
| Frequency range | 45 Hz ... 55 Hz |
| Current consumption | 3 A |
| Permissible backup fuse | B6 B10 B16 |
Connection data, input
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 10 mm |
Output data
| Apparent power | 750 VA |
|---|---|
| Rated Power (Real Power) | 600 W |
| Power factor (cos phi) | 0.8 |
| Crest factor | 2.8 |
| Switch-over time | < 10 ms |
| Classification according to IEC 62040-3 | VFD-SS-311 |
Output data (mains operation)
| Nominal output voltage (UN) | 230 V AC |
|---|---|
| Nominal output current (IN) | 3 A (750 VA) |
Output data (battery operation)
| Nominal output voltage (UN) | 230 V AC |
|---|---|
| Nominal output current (IN) | 3 A (750 VA) |
| Form of output voltage | Pure sine |
| Frequency (after automatic detection in mains operation) | 50 Hz |
| 60 Hz |
Connection data, output
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 10 mm |
General data
| Efficiency | > 95 % (with charged energy storage device) |
|---|---|
| MTBF (IEC 61709, SN 29500) | > 206000 h (40°C) |
| Degree of protection | IP20 |
| Protection class | I |
| Type of housing | Steel sheet, zinc-plated |
| Hood version | PC + ABS |
| Input fuse | 10 A 400 V gRL |
| Weight | 5.7 kg |
Energy storage
| Battery technology | Lead rechargeable battery module |
|---|---|
| Battery type | 2x Panasonic UP-VW1220P1 |
| Capacity | 3.4 Ah |
| Battery fuse | 40 A, 32 V |
| Charging time | 7 h |
| Service life | 6 Years ... 9 Years (20 °C) |
| Latest startup | 6 Months (0 °C ... 20 °C) |
| Buffer period | 20 min. (100 W) |
| 4 min. (300 W) | |
| 1 min. (600 W) | |
| Can be extended with external battery | 1x 24 V 3.4 Ah |
Connection data for the external battery
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 10 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 6 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 8 |
| Stripping length | 15 mm |
Status and diagnostics indicator / signal outputs - Alarm
| Switching output | Transistor output, active |
|---|---|
| Output voltage | 24 V (SELV) |
| Continuous load current | ≤ 20 mA |
| Status display | LED red |
Status and diagnostics indicator / signal outputs - Battery Mode
| Switching output | Transistor output, active |
|---|---|
| Output voltage | 24 V (SELV) |
| Continuous load current | ≤ 20 mA |
| Status display | Yellow LED |
Status and diagnostics indicator / signal outputs - Ready
| Switching output | Transistor output, active |
|---|---|
| Output voltage | 24 V (SELV) |
| Continuous load current | ≤ 20 mA |
Connection data for signaling
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Remote control
| Designation | Remote |
|---|---|
| Low signal | Connection to SGnd with < 2.7 kΩ |
| High signal | Open (> 35 kΩ between remote and SGnd) |
Battery-operated start (bat. start)
| Low signal | Connection to SGnd with < 2.7 kΩ |
|---|---|
| High signal | Open (> 200 kΩ between bat. start and SGnd) |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Noise immunity | Noise immunity according to EN 62040-2-2006 |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 4 kV (Test Level 2) |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 80 MHz ... 1 GHz |
| Test field strength | 10 V/m |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Standards/regulations | EN 61000-4-6 |
| Frequency range | 0.15 MHz ... 80 MHz |
| Voltage | 10 V |
| Conducted noise emission | EN 55016 EN 62040-02 (Class C2) |
| Standards/regulations | EN 61000-4-8 |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| Shock | 20g in all directions (EN 60068-2-27) |
| Vibration (operation) | 5 Hz ... 100 Hz, 0.7g (EN 60068-2-6) |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 3 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |