TRIO-PS67/1AC/24DC/10/M12/5P 1395808 PHOENIX CONTACT TRIO POWER primary switching power supply in IP67 die-c..
TRIO-PS67/1AC/24DC/10/M12/5P
1395808
PHOENIX CONTACT
1 Pcs.
Automation > DC-power supply
Power Supplies (PS)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
TRIO POWER primary switching power supply in IP67 die-c.. 1395808 built by Phoenix Contact is designed to deliver robust energy conversion in demanding environments exposed to dust and moisture. Such protected power supplies are installed directly on machine frames outside traditional enclosures to energize decentralized automation equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- AC Operation Network Structure: Star Network (TN, TT, IT (PE))
- Nominal Input Voltage Range: 120 V AC ... 240 V AC
- Input Voltage Range: 120 V AC ... 240 V AC ±10%
- Operating Voltage: > 85 V AC
- Disconnect voltage: < 85 V AC
- Maximum dielectric strength: ≤ 300 V AC 15 sec
- Typical Country Grid Voltage: 120 V AC
- Supply Voltage Voltage Type: AC
- Extra-current shut-off: ≤ 25 A (typical)
- Inrush current integral (I 2 t): < 0.5 A 2 s
- Shut-off current voltage limitation: Typ. 25 A (after 1 ms)
- AC Frequency Range: 50 Hz ... 60 Hz ±10%
- Frequency range (f N ): 50 Hz ... 60 Hz ±10%
- Network Failure Bridging Time: > 17 ms (120 V AC)
- Current absorption: 2.3 A (120 V AC)
- Nominal power input: 285 VA
More info
▲| AC Operation | |
| Network Structure | Star Network (TN, TT, IT (PE)) |
| Nominal Input Voltage Range | 120 V AC ... 240 V AC |
| Input Voltage Range | 120 V AC ... 240 V AC ±10% |
| Operating Voltage | > 85 V AC |
| Disconnect voltage | < 85 V AC |
| Maximum dielectric strength | ≤ 300 V AC 15 sec |
| Typical Country Grid Voltage | 120 V AC |
| 230 V AC | |
| Supply Voltage Voltage Type | AC |
| Extra-current shut-off | ≤ 25 A (typical) |
| Inrush current integral (I2t) | < 0.5 A2s |
| Shut-off current voltage limitation | Typ. 25 A (after 1 ms) |
| AC Frequency Range | 50 Hz ... 60 Hz ±10% |
| Frequency range (fN) | 50 Hz ... 60 Hz ±10% |
| Network Failure Bridging Time | > 17 ms (120 V AC) |
| > 17 ms (230 V AC) | |
| Current absorption | 2.3 A (120 V AC) |
| 1.2 A (240 V AC) | |
| Nominal power input | 285 VA |
| Protection Circuit | Protection against transient overvoltages; Varistor |
| Connection Time | < 1 sec |
| Inlet fuse | 6.3 A (internal (device protection)) |
| Selecting the Right Fuse for Ingress Protection | 6 A ... 16 A (US/CAN: branch circuit protection |
| Ground Shunt Current (PE) | < 3.5 mA |
| Yield | Typ. 90% (120 V AC) |
| Typ. 92% (230 V AC) | |
| Nominal Output Voltage | 24 V DC ±1% |
| Rated Output Current (IN) | 10 A |
| Static Boost (IBoost est.) | 12.5 A (UN 230 V AC) |
| Static boost derating | > 40 °C ... 50 °C 1 %/K> 50 ... 60 °C 0.22 %/K (UN 230 V AC, PStat.Boost= PNx 1:25) |
| Dynamic Boost (IDyn.Boost) | 15 A (5 sec) |
| Derating | > 40 °C ... 50 °C (1%/K) |
| Recirculation Resistance | ≤ 35 V DC |
| Output Surge Protection (OVP) | ≤ 30 V DC |
| Dimming deviation | < 1% (static load change 10% ... 90 %) |
| < 3% (Dynamic Load Change 10 ... 90%, 10 Hz) | |
| < 0.1% (input voltage change ±10%) | |
| Residual ripple | ≤ 10 mVPP |
| Short circuit resistant | Yes |
| Output power | 240 W |
| 300 W | |
| 360 W (5 sec) | |
| Maximum Open Circuit Dissipation | < 2 W (120 V AC) |
| < 2 W (230 V AC) | |
| Maximum Rated Load Dissipation | < 25 W (120 V AC) |
| < 21 W (230 V AC) | |
| Ascent Time | ≤ 12 ms (UOUT(10 % ... 90 %)) |
| Parallel connection possible | Yes, for redundancy and power boost |
| Possibility of series connection | Yes |
| Relay signal 13/14 | |
| Default | closed |
| Digital | 30 V AC 30 V DC 100 mA |
| entrance | |
| Connection type | M12 Cylindrical Connector |
| Codification | s |
| Lock Type | M12 Screw Lock |
| Number of poles | 3 |
| Exit | |
| Connection type | M12 Cylindrical Connector |
| Codification | L |
| Lock Type | M12 Screw Lock |
| Number of poles | 5 |
| Type of signage | LED |
| Potential-free signal contact | |
| Status Indication | 2 x Green LED |
| Signal Output: LED Status Indication | |
| Designation Signage | AC OK |
| Status Indication | LED |
| Colour | green |
| AC OK | AcIn> 0.45 x ACN(ACN= 108 V AC) |
| Signal Output: LED Status Indication | |
| Designation Signage | DC OK |
| DC OK | UOUT> 0.9 x UN(UN= 24 V DC) |
| Number of phases | 1,00 |
| Input/Output Insulation Voltage | 3 kV AC (type test) |
| 1.5 kV AC (Single test) |
| Product Type | Power supply |
| Product Family | TRIO POWER |
| MTBF (IEC 61709, SN 29500) | > 850000 h (25 °C) |
| > 460000 h (40 °C) | |
| > 190000 h (60 °C) | |
| Insulation Properties | |
| Kind of protection | I |
| Degree of pollution | 3 |
| Item Dimensions | |
| Width | 136 mm |
| Height | 240 mm |
| Depth | 53 mm |
| Orifice | |
| Diameter | 5.6 mm |
| Mounting Size | |
| Right/Left Mounting Distance | 20 mm / 20 mm |
| Mounting Distance Up/Down | 50 mm / 100 mm |
| Type of mounting | Wall Mounting |
| Installation instructions | Stackable: horizontal 20 mm, vertical up 50 mm, vertical down 100 mm |
| With protective paint | No |
| Flammability class according to UL 94 (housing/terminals) | V0 |
| Housing Material | Metal |
| Execution of the housings | Aluminum (AlMg3) |
| Environmental conditions | |
| Protection Index | IP67 |
| Ambient Temperature (Service) | -25 °C ... 60 °C |
| Ambient Temperature (Storage/Transport) | -40 °C ... 85 °C |
| Ambient temperature (Start-Up tested model) | -40 °C |
| Fixing height | ≤ 4000 m (> 2000 m, Derating: 10%/1000 m) |
| Weather Class | 4K26 (EN 60721-3-4) |
| Max. permissible air humidity (service) | ≤ 100% (at 25°C, non-condensing) |
| Permissible air humidity (service) | ≤ 100% (at 25°C, non-condensing) |
| Crash | 18 ms, 30g, per direction in space (according to IEC 60068-2-27) |
| Vibration (service) | < 15 Hz, width ±2.5 mm (according to IEC 60068-2-6) |
| 15 Hz ... 150 Hz, 4g, 90 min. | |
| Surge Category | |
| EN 61010-1 | III (≤ 2000 m) |
| II (≤ 4000 m) | |
| Electrical Safety | |
| Denomination of standard | Electrical Safety |
| Rules/Provisions | IEC 61010-1 |
| Minimum protective voltage with safe insulation | |
| Denomination of standard | Minimum protective voltage with safe insulation |
| Rules/Provisions | IEC 61010-1 (SELV) |
| IEC 61010-2-201 (PELV) | |
| Secure Isolation | |
| Denomination of standard | Safe Separation |
| Low-voltage power supplies with direct current output | |
| Denomination of standard | Low-voltage power supplies with direct current output |
| Rules/Provisions | EN 61204-3 |
| Safety Standards for Electrical Measurement, Control, Regulation, and Laboratory Equipment | |
| Denomination of standard | Safety Standards for Electrical Measurement, Control, Regulation, and Laboratory Devices |
| Rules/Provisions | IEC 61010-1 |
| Limit values for harmonic currents | |
| Denomination of standard | Limit values for harmonic currents |
| Rules/Provisions | EN 61000-3-2 |
| Enclosure protection ratings (IP code) | |
| Denomination of standard | Enclosure protection ratings (IP code) |
| Rules/Provisions | EN/IEC 60529 |
| Ul | |
| Marked | UL/C-UL Listed UL 61010-1 |
| Ul | |
| Marked | UL/C-UL Listed UL 61010-2-201 |
| Low Voltage Directive | Compliance with the Low Voltage Directive 2014/35/EU |
| Interference emission | Interference emission in accordance with EN 61000-6-3 (residential and commercial areas) and EN 61000-6-4 (industrial areas) |
| Interference resistance | Immunity to interference according to EN 61000-6-1 (domestic use), EN 61000-6-2 (industrial use) |
| Electromagnetic compatibility | Compliance with EMC Directive 2014/30/EU |
| Emission of Conducted Interference | EN 55016 |
| EN 61000-6-3 (class B) | |
| Interference emission | EN 55011 (EN 55022) |
| Radiated spurious emissions | EN 55016 |
| EN 61000-6-3 (class B) | |
| Harmonic currents | |
| Standards/Specifications | EN 61000-3-2 |
| EN 61000-3-2 (class A) | |
| Static Electricity Discharge | |
| Standards/Specifications | EN 61000-4-2 |
| Static Electricity Discharge | |
| Download contact us | 6 kV (Test Severity 3) |
| Observation | Criterion A |
| Electromagnetic field AF | |
| Standards/Specifications | EN 61000-4-3 |
| Electromagnetic field AF | |
| Frequency Range | 80 MHz ... 1 GHz |
| Test Field Intensity | 10 V/m (Test Severity 3) |
| Frequency Range | 1 GHz ... 2 GHz |
| Test Field Intensity | 10 V/m (Test Severity 3) |
| Frequency Range | 2 GHz ... 6 GHz |
| Test Field Intensity | 10 V/m (Test Severity 3) |
| Observation | Criterion A |
| Fast Transients (Burst) | |
| Standards/Specifications | EN 61000-4-4 |
| Fast Transients (Burst) | |
| entrance | 4 kV (Test Severity 3, Asymmetric) |
| Exit | 2 kV (Test Severity 3, Asymmetric) |
| Signal | 2 kV (Test Severity 3, Asymmetric) |
| Observation | Criterion A |
| Transient Voltage Load (Surge) | |
| Standards/Specifications | EN 61000-4-5 |
| entrance | 2 kV (Test Severity 4, Symmetrical) |
| 4 kV (Test Severity 4, Asymmetric) | |
| Exit | 1 kV (Test Severity 3, Symmetrical) |
| 2 kV (Test Severity 3, Asymmetric) | |
| Signal | 1 kV (Test Severity 2, Asymmetric) |
| Observation | Criterion A |
| Conducted Disturbances | |
| Standards/Specifications | EN 61000-4-6 |
| Conducted Disturbances | |
| Input/Output | asymmetric |
| Frequency Range | 0.15 MHz ... 80 MHz |
| Observation | Criterion A |
| tension | 10 V (Test Severity 3) |
| Voltage drops | |
| Standards/Specifications | EN 61000-4-11 |
| tension | 230 V AC |
| frequency | 50 Hz |
| Voltage Error | 70 % |
| Number of periods | 25 periods |
| Observation | Criterion A |
| Voltage Error | 40 % |
| Number of periods | 10 periods |
| Observation | Criterion A |
| Voltage Error | 0 % |
| Number of periods | 1 period |
| Observation | Criterion A |
| Interference emission | |
| Standards/Specifications | EN 61000-6-3 |
| Radio interference voltage according to EN 55011 | EN 55011 (EN 55022) Class B Application in industry and residential |
| Radio interference according to EN 55011 | EN 55011 (EN 55022) Class B Application in industry and residential |
| Criteria | |
| Criterion A | Normal service behavior within the specified limits. |
| Criterion B | Transient alteration of service behavior, which is corrected by the device itself. |
| Criterion C | Temporary adverse effects on performance that are automatically corrected by the equipment or that can be reset by operating the control elements. |