PHOENIX CONTACT MACX MCR-T-UIREL-UP-SP MACX MCR-T-UIREL-UP-SP 2811828 PHOENIX CONTACT Temperature measuring transducer View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MACX MCR-T-UIREL-UP-SP 2811828 PHOENIX CONTACT Temperature measuring transducer

MACX MCR-T-UIREL-UP-SP

2811828

PHOENIX CONTACT

1 Pcs.

Temperature measuring transducer Freely programmable temperature converter with analogue output and 3 limit value relays, standard configuration, heat resistance in 2, 3 or 4 conductor technology, thermocouples, galvanic separation, wide power range, push-in connection, SIL, PL.

Automation > Temperature transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The MACX MCR-T-UIREL-UP-SP 2811828 PHOENIX CONTACT Temperature measuring transducer provides reliable signal conversion and threshold monitoring for complex thermal instrumentation networks. Engineers integrate such transducers into control architectures to bridge temperature sensors with automation hardware while offering relay switching capabilities.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Measuring range (EF001836): -250 °C
  • Analogue output 4 mA ... 20 mA (EF006810): Yes
  • With switching output (EF005225): Yes
  • EMC-version (EF001062): Yes
  • Ambient temperature (EF002386): 65 °C
  • Weight (EF000167): 0.12 kg

More info

▲

Key Commercial Data

Orderkey2811828
Packing unit1 pc
Catalog pagePage 127 (C-5-2017)
GTIN4046356579483
Weight per Piece (excluding packing)120.000 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width35 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)typ. 5 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.

Input data

Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
Input signal range0 Ω ... 50 kΩ
Potentiometer resistance range0 Ω ... 50 kΩ
Input signal range-1000 mV ... 1000 mV

Output data

Configurable/programmableYes
Max. voltage output signal± 11 V
Current output signal4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
Max. current output signal22 mA
Load/output load voltage output≥ 10 kΩ
Load/output load current output≤ 600 Ω (at 20 mA)
Behavior in the event of a sensor erroraccording to NE 43 or freely configurable
Output nameRelay output
Configurable/programmableYes
Contact type3 PDTs
Contact materialAgSnO2, hard gold-plated
Maximum switching voltage250 V AC (250 V DC)
Maximum inrush current2 A (250 V AC)
2 A (28 V DC)

Power supply

Supply voltage range24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Power consumption< 2.4 W

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm
Connection methodPush-in connection

General

Maximum transmission error0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Maximum temperature coefficient0.01 %/K
Flammability rating according to UL 94V0
Degree of pollution2
Overvoltage categoryII
Electromagnetic compatibilityConformance with EMC directive
Housing materialPA 6.6-FR
Colorgray
DesignationInput/output/power supply
Electrical isolation300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/switching output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant
ATEX II 3 G Ex nA nC ic IIC T4 Gc X
IECExEx nA nC ic IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
SIL2

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Electrical isolation4-way, between input/output/power supply/switching output
Flammability rating according to UL 94V0
ConformanceCE-compliant
ATEX II 3 G Ex nA nC ic IIC T4 Gc X
IECExEx nA nC ic IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
DNV GL-TemperatureB
DNV GL-HumidityB
DNV GL-VibrationA
DNV GL-EMCA
DNV GL-EnclosureRequired protection according to the Rules shall be provided upon installation on board

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.