PHOENIX CONTACT UTWE 6/4+1 BI UTWE 6/4+1 BI 3070008 PHOENIX CONTACT Test terminal strip View larger
Images are for illustrative purposes only. Please refer to data sheet for details

UTWE 6/4+1 BI 3070008 PHOENIX CONTACT Test terminal strip

UTWE 6/4+1 BI

3070008

PHOENIX CONTACT

5 Pcs.

Test terminal strip Test pin strip, rated voltage: 400 V, rated current: 24 A, number of connections: 10, number of poles: 5, connection type: Screw connection, 1st floor, Sizing cross-section: 6 mm², cross-section: 0.2 mm² - 10 mm², mounting class: Wall mounting, color: gray Test terminal strip, nom. voltage: 400 V, nominal current: 24 A, number of connections: 10, number of positions: 5, connection method: Screw connection, 1 level, Rated cross section: 6 mm2, cross section: 0.2 mm2 - 10 mm2, mounting type: Wall mounting, color: gray

Automation > Test plug for terminal blocks
Enclosures connectivity

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Built for rigorous industrial environments, the Phoenix Contact UTWE 6/4+1 BI test terminal strip provides structured management of test signals and measurement pathways. Terminal strips ensure that technicians can safely isolate specific circuits during maintenance without compromising system integrity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Test terminal strip
  • Number of positions: 5
  • Pitch: 8.2 mm
  • Number of connections: 10
  • Number of rows: 1
  • Potentials: 5
  • Insulation characteristics Overvoltage category: III
  • Rated surge voltage: 4 kV
  • Maximum power dissipation for nominal condition: 1.31 W
  • Test surge voltage: 5 kV
  • Number of connections per level: 10
  • Nominal cross section: 6 mm²
  • 1 level Screw thread: M4
  • Tightening torque: 1.5 ... 1.8 Nm
  • Stripping length: 10 mm
  • Internal cylindrical gage: A5

More info

▲
Technical data

Product properties
Product typeTest terminal strip
Number of positions5
Pitch8.2 mm
Number of connections10
Number of rows1
Potentials5
Insulation characteristics
Overvoltage categoryIII

Electrical properties
Rated surge voltage4 kV
Maximum power dissipation for nominal condition1.31 W
Test surge voltage5 kV

Connection data
Number of connections per level10
Nominal cross section6 mm²
1 level
Screw threadM4
Tightening torque1.5 ... 1.8 Nm
Stripping length10 mm
Internal cylindrical gageA5
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.2 mm² ... 10 mm²
Cross section AWG24 ... 8 (converted acc. to IEC)
Conductor cross section flexible0.2 mm² ... 10 mm²
Conductor cross section, flexible [AWG]24 ... 8 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 6 mm²
2 conductors with same cross section, solid0.2 mm² ... 2.5 mm²
2 conductors with same cross section, flexible0.2 mm² ... 2.5 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 2.5 mm²
Nominal current24 A
Maximum load current30 A (with 10 mm² conductor cross section)
Nominal voltage400 V AC/DC
Nominal cross section6 mm²

Dimensions
Dimensional drawing
Width107 mm
Height81 mm
Depth81 mm
Pitch8.2 mm
Plate thickness1 mm ... 4 mm

Material specifications
Colorgray (RAL 7042)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Mechanical properties
General
Terminal block mounting0.8 Nm ... 1 Nm
Mechanical data
Open side panelNo

Environmental and real-life conditions
Ambient conditions
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60947-7-1

Mounting
Mounting typeWall mounting
Terminal block mounting0.8 Nm ... 1 Nm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.