FTP-2/1 SERVICE 3069469 PHOENIX CONTACT Test plug
FTP-2/1 SERVICE
3069469
PHOENIX CONTACT
1 Pcs.
Automation > Test plug for terminal blocks
Enclosures connectivity
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact FTP-2/1 SERVICE test plug (part number FTP-2/1 SERVICE) is a specialized terminal block accessory engineered for safely routing and managing measurement signals during routine maintenance and diagnostic testing of electrical switchgear. Such test plugs allow technicians to tap into active circuits without interrupting normal system operations, facilitating secure multimeter or diagnostic tool connections in industrial control panels.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Test plug terminal block
- Number of positions: 1
- Pitch: 8.2 mm
- Number of connections: 2
- Number of rows: 1
- Potentials: 1
- Data management status Article revision: 08
- Insulation characteristics Overvoltage category: III
- Rated surge voltage: 4 kV
- Maximum power dissipation for nominal condition: 1.31 W
- Test surge voltage: 5 kV
- Nominal cross section: 6 mm²
- Test socket torque: 0.5
- Note: The conductor cross section depends on the cable lug used
- Conductor cross section flexible: 0.5 mm² ... 2.5 mm²
- Conductor cross section, flexible [AWG]: 20 ... 14 (converted acc. to IEC)
More info
▲| Product type | Test plug terminal block |
| Number of positions | 1 |
| Pitch | 8.2 mm |
| Number of connections | 2 |
| Number of rows | 1 |
| Potentials | 1 |
| Data management status | |
| Article revision | 08 |
| Insulation characteristics | |
| Overvoltage category | III |
| Rated surge voltage | 4 kV |
| Maximum power dissipation for nominal condition | 1.31 W |
| Test surge voltage | 5 kV |
| Nominal cross section | 6 mm² |
| Test socket torque | 0.5 |
| Note | The conductor cross section depends on the cable lug used |
| Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
| Conductor cross section, flexible [AWG] | 20 ... 14 (converted acc. to IEC) |
| Nominal current | 24 A |
| Maximum load current | 24 A |
| Nominal voltage | 400 V AC/DC |
| Nominal cross section | 2.5 mm² |
| Width | 9 mm |
| Height | 86 mm |
| Pitch | 8.2 mm |
| Color | red (RAL 3001) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Mechanical data | |
| Open side panel | No |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Mounting type | Insertion in base strip |