Designed for high-density wiring environments, the Phoenix Contact ST 2,5-3L-LA 24RD/O-M multi-level terminal block organizes complex signal and power circuits on standard DIN rails. Multi-level blocks save valuable panel space by stacking multiple electrical connection points vertically within a single housing. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Connectable conductor cross section solid-core (EF007337): 0.08 mm²
- Rated current In (EF008250): 20 A
- Rated voltage (EF000228): 500 V
- Type of electrical connection 1 (EF002526): Spring clamp connection
- Type of electrical connection 2 (EF002527): Spring clamp connection
- Number of levels (EF002659): 3
- Number of clamp positions per level (EF002660): 2
- Suitable for conductor material (EF012572): Aluminium/copper
- Mounting method (EF000003): DIN rail (top hat rail) 35 mm
- Width (EF000008): 5.2 mm
- Height (EF000040): 99.5 mm
- Depth (EF000049): 58 mm
- Closing plate required (EF002525): Yes
- Colour (EF000007): Grey
- Internally connected stages (EF002661): No
More info
▲Key Commercial Data
| Orderkey | 3035580 |
|---|---|
| Packing unit | 50 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 159 (C-1-2017) |
| GTIN | 4046356435932 |
| Weight per Piece (excluding packing) | 18.260 g |
| Custom tariff number | 85369010 |
| Country of origin | PL (Poland) |
General
| Number of levels | 3 |
|---|---|
| Number of connections | 6 |
| Potentials | 3 |
| Nominal cross section | 2.5 mm² |
| Color | gray |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Rated surge voltage | 6 kV |
| LED voltage range | 12 V AC/DC ... 30 V AC/DC |
| LED current range | 0.31 mA ... 0.95 mA |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Maximum power dissipation for nominal condition | 0.77 W (the value is multiplied when connecting multiple levels) |
| Maximum load current | 28 A (with 4 mm² conductor cross section) |
| Nominal current IN | 20 A |
| Nominal voltage UN | 500 V (the operating voltage is determined by the selected LED version) |
| Open side panel | Yes |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
| Static insulating material application in cold | -60 °C |
| Behavior in fire for rail vehicles (DIN 5510-2) | Test passed |
| Flame test method (DIN EN 60695-11-10) | V0 |
| Oxygen index (DIN EN ISO 4589-2) | >32 % |
| NF F16-101, NF F10-102 Class I | 2 |
| NF F16-101, NF F10-102 Class F | 2 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Connection data
| Connection method | Spring-cage connection |
|---|---|
| Stripping length | 8 mm ... 10 mm |
| Conductor cross section solid min. | 0.08 mm² |
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section AWG min. | 28 |
| Conductor cross section AWG max. | 12 |
| Conductor cross section flexible min. | 0.08 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Min. AWG conductor cross section, flexible | 28 |
| Max. AWG conductor cross section, flexible | 14 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 0.5 mm² |
| Internal cylindrical gage | A3 |
Standards and Regulations
| Flammability rating according to UL 94 | V0 |
|---|---|
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |