View larger
QTCS 1,5-TWIN-PE 3206364 PHOENIX CONTACT Ground modular terminal block
QTCS 1,5-TWIN-PE
3206364
PHOENIX CONTACT
50 Pcs.
Automation > Ground terminal block
Enclosures connectivity
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing specialized twin connections for protective grounding, the Phoenix Contact QTCS 1,5-TWIN-PE ground modular terminal block organizes earthing lines efficiently within confined control panels. These components ensure continuous safety grounding by linking multiple conductors to a shared potential rail.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 3206364
- Packing unit: 50 pc
- Minimum order quantity: 50 pc
- Note: Made to Order (non-returnable)
- Catalog page: Page 207 (C-1-2017)
- GTIN: 4017918975999
- Weight per Piece (excluding packing): 13.310 g
- Custom tariff number: 85369010
- Country of origin: CN (China)
- Number of levels: 1
- Number of connections: 3
- Nominal cross section: 1.5 mm²
- Color: green-yellow
- Insulating material: PA
- Flammability rating according to UL 94: V0
- Rated surge voltage: 8 kV
More info
▲Key Commercial Data
| Orderkey | 3206364 |
|---|---|
| Packing unit | 50 pc |
| Minimum order quantity | 50 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 207 (C-1-2017) |
| GTIN | 4017918975999 |
| Weight per Piece (excluding packing) | 13.310 g |
| Custom tariff number | 85369010 |
| Country of origin | CN (China) |
General
| Number of levels | 1 |
|---|---|
| Number of connections | 3 |
| Nominal cross section | 1.5 mm² |
| Color | green-yellow |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Rated surge voltage | 8 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Ambient temperature (actuation) | -10 °C ... 90 °C |
| Connection method | Quick connection |
| Connection in acc. with standard | IEC 60947-7-2 |
| Connection method | Spring-cage connection |
| Connection in acc. with standard | IEC 60947-7-2 |
| Open side panel | Yes |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
| Static insulating material application in cold | -60 °C |
| Behavior in fire for rail vehicles (DIN 5510-2) | Test passed |
| Flame test method (DIN EN 60695-11-10) | V0 |
| Oxygen index (DIN EN ISO 4589-2) | >32 % |
| NF F16-101, NF F10-102 Class I | 2 |
| NF F16-101, NF F10-102 Class F | 2 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Dimensions
| Width | 5.2 mm |
|---|---|
| Length | 71.6 mm |
| Height NS 35/7,5 | 39.3 mm |
| Height NS 35/15 | 46.8 mm |
| End cover width | 2.2 mm |
Connection data
| Connection method | Quick connection |
|---|---|
| Connection in acc. with standard | IEC 60947-7-2 |
| Note | Please observe the current carrying capacity of the DIN rails. |
| Max. wire diameter incl. insulation | 3 mm |
| Conductor cross section solid min. | 0.25 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Conductor cross section flexible min. | 0.25 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Min. AWG conductor cross section, flexible | 24 |
| Max. AWG conductor cross section, flexible | 16 |
| Conductor cross section flexible min. after 10 connections with the max. solid conductor | 0.25 mm² |
| Conductor cross section flexible max. after 10 connections with the max. solid conductor | 1.5 mm² |
| Conductor cross section solid min. after 10 connections with the max. solid conductor | 0.25 mm² |
| Conductor cross section solid max. after 10 connections with the max. solid conductor | 1.5 mm² |
| AWG min. after 10 connections with the max. rigid conductor | 24 |
| AWG max. after 10 connections with the max. rigid conductor | 16 |
| Cross section sensor cables, min. | 0.25 mm² |
| Cross section sensor cables, max. | 0.34 mm² |
| Connection in acc. with standard | IEC/EN 60079-7 |
| Test certificate name | KEMA 04ATEX2226 U |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Material wire insulation | PVC / PE |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| IEC 60947-7-2 | |
| IEC 60947-7-2 | |
| Flammability rating according to UL 94 | V0 |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |