View larger
QTC 2,5-HESI (5X20) 3050293 PHOENIX CONTACT Fuse modular terminal block
QTC 2,5-HESI (5X20)
3050293
PHOENIX CONTACT
50 Pcs.
Automation > Fuse terminal block
Enclosures connectivity
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact QTC 2,5-HESI (5X20) fuse modular terminal block provides organized circuit protection within industrial control cabinets and railway infrastructure. Fuse terminal blocks protect sensitive wiring branches and connected instrumentation by securely housing standard cylindrical fuses directly on mounting rails. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- General: The current is determined by the fuse used, the voltage by the light indicator.:
- Product type: Fuse terminal block
- Area of application: Railway industry
- Number of connections: 2
- Number of rows: 1
- Potentials: 1
- Data management status Article revision: 07
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Fuse type: Glass / ceramics / ...
- Rated surge voltage: 6 kV
- Maximum power dissipation for nominal condition: 0.77 W
- Fuse: G / 5 x 20
- Maximum power dissipation: max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
- Number of connections per level: 2
- Frequency of connections with the same cross section: 100.00
More info
▲| General | The current is determined by the fuse used, the voltage by the light indicator. |
| Product type | Fuse terminal block |
| Area of application | Railway industry |
| Machine building | |
| Plant engineering | |
| Number of connections | 2 |
| Number of rows | 1 |
| Potentials | 1 |
| Data management status | |
| Article revision | 07 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Fuse type | Glass / ceramics / ... |
| Rated surge voltage | 6 kV |
| Maximum power dissipation for nominal condition | 0.77 W |
| Fuse | G / 5 x 20 |
| Maximum power dissipation | max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload) |
| max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) | |
| max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit) | |
| max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit) |
| Number of connections per level | 2 |
| Frequency of connections with the same cross section | 100.00 |
| Nominal cross section | 2.5 mm² |
| 1 level | |
| Connection in acc. with standard | IEC 60947-7-3 |
| Conductor cross section rigid | 0.5 mm² ... 2.5 mm² |
| Cross section AWG | 20 ... 14 (converted acc. to IEC) |
| Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
| Conductor cross section, flexible [AWG] | 20 ... 14 (converted acc. to IEC) |
| Nominal current | 6.3 A |
| Maximum load current | 6.3 A (the current is determined by the fuse used) |
| Nominal voltage | 500 V |
| Nominal cross section | 1.5 mm² |
| Width | 6.2 mm |
| End cover width | 2.2 mm |
| Height | 82.5 mm |
| Depth on NS 35/7,5 | 64.9 mm |
| Depth on NS 35/15 | 72.4 mm |
| Color | black (RAL 9005) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Wire diameter incl. insulation | 3.8 mm |
| Mechanical data | |
| Open side panel | Yes |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Connection in acc. with standard | IEC 60947-7-3 |
| Mounting type | NS 35/7,5 |
| NS 35/15 |