View larger
MACX MCR-T-UI-UP 2811394 PHOENIX CONTACT Freely programmable temperature transducer with analog output and 1..
MACX MCR-T-UI-UP
2811394
PHOENIX CONTACT
1 Pcs.
Automation > Temperature transformer
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A MACX MCR-T-UI-UP 2811394 PHOENIX CONTACT Freely programmable temperature transducer with analog output is an advanced signal conversion module used widely in industrial automation environments. Devices of this category take raw sensor inputs from thermocouples or resistance detectors and scale them into dependable control signals for PLCs and monitoring instrumentation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Measuring range (EF001836): -250 °C
- Analogue output 4 mA ... 20 mA (EF006810): Yes
- With switching output (EF005225): Yes
- EMC-version (EF001062): Yes
- Ambient temperature (EF002386): 65 °C
- Weight (EF000167): 0.1939 kg
More info
▲Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Dimensions
| Width | 17.5 mm |
|---|---|
| Height | 99 mm |
| Depth | 114.5 mm |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 65 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | ≤ 2000 m |
| Permissible humidity (operation) | typ. 5 % ... 95 % (non-condensing) |
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Input data
| Sensor types (RTD) that can be used | Pt, Ni, Cu sensors: 2, 3, 4-wire |
|---|---|
| Sensor types that can be used (TC) | B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG |
| Temperature measuring range | -250 °C ... 2500 °C (Range depending on the sensor type) |
| Input signal range | 0 Ω ... 50 kΩ |
| Potentiometer resistance range | 0 Ω ... 50 kΩ |
| Input signal range | -1000 mV ... 1000 mV |
Output data
| Max. voltage output signal | ± 11 V |
|---|---|
| Current output signal | 0 mA ... 20 mA ±10 V (in the case of SIL; further free configuration without SIL) |
| Max. current output signal | 22 mA |
| Load/output load voltage output | ≥ 10 kΩ |
| Load/output load current output | ≤ 600 Ω (20 mA) |
| Behavior in the event of a sensor error | according to NE 43 or freely configurable |
| Output name | Relay output |
| Contact type | 1 PDT |
| Contact material | AgSnO2, hard gold-plated |
| Maximum switching voltage | 30 V AC (30 V DC) |
| Maximum inrush current | 0.5 A (30 V AC) |
| 1 A (30 V DC) |
Power supply
| Supply voltage range | 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz) |
|---|---|
| Power consumption | < 1.5 W |
Connection data
| Conductor cross section solid min. | 0.2 mm² |
|---|---|
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Connection method | Screw connection |
General
| Maximum temperature coefficient | 0.01 %/K |
|---|---|
| Flammability rating according to UL 94 | V0 |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Electromagnetic compatibility | Conformance with EMC directive |
| Housing material | PA 66-FR |
| Color | green |
| Designation | Input/output/power supply |
| Electrical isolation | 300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1)) |
| 2.5 kV (50 Hz, 1 min., test voltage) | |
| Designation | Input/output |
| Electrical isolation | 375 V (Peak value in accordance with EN 60079-11) |
| Designation | Input/power supply |
| Electrical isolation | 375 V (Peak value in accordance with EN 60079-11) |
| Designation | Input/switching output |
| Electrical isolation | 375 V (Peak value in accordance with EN 60079-11) |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA nC ic IIC T4 Gc X |
| IECEx | Ex nA nC ic IIC T4 Gc X |
| UL, USA / Canada | UL 508 Listed |
| Class I, Div. 2, Groups A, B, C, D T6 | |
| Class I, Zone 2, Group IIC T6 | |
| Functional Safety (SIL) | SIL 2 |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC directive |
|---|---|
| Electrical isolation | 4-way, between input/output/power supply/switching output |
| Flammability rating according to UL 94 | V0 |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA nC ic IIC T4 Gc X |
| IECEx | Ex nA nC ic IIC T4 Gc X |
| UL, USA / Canada | UL 508 Listed |
| Class I, Div. 2, Groups A, B, C, D T6 | |
| Class I, Zone 2, Group IIC T6 |
eCl@ss
| eCl@ss 4.0 | 27210107 |
|---|---|
| eCl@ss 4.1 | 27210107 |
| eCl@ss 5.0 | 27210107 |
| eCl@ss 5.1 | 27210107 |
| eCl@ss 6.0 | 27210107 |
| eCl@ss 7.0 | 27210107 |
| eCl@ss 8.0 | 27371503 |
ETIM
| ETIM 4.0 | EC001596 |
|---|---|
| ETIM 5.0 | EC002568 |
UNSPSC
| UNSPSC 6.01 | 30211506 |
|---|---|
| UNSPSC 7.0901 | 39121008 |
| UNSPSC 11 | 39121008 |
| UNSPSC 12.01 | 39121008 |
| UNSPSC 13.2 | 39121008 |