View larger
TCP 5A 1538622 PHOENIX CONTACT Single-channel thermal switch for equipment protection, to protect consumers ..
TCP 5A
1538622
PHOENIX CONTACT
1 Pcs.
Automation > Device circuit breaker
Over Current Protection
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Specialized equipment protection is achieved using the Phoenix Contact TCP 5A single-channel thermal switch for equipment protection, to protect consumers .., designed to shield connected consumers from thermal stress. Thermal switches of this classification are frequently built into electrical distribution units to disconnect faulty circuits before excessive heat damages equipment. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type: Male
- Product type: Thermal device circuit breakers
- Number of positions: 1
- Insulation characteristics Overvoltage category: II
- Degree of pollution: 2
- Fuse type: Automatic device
- Maximum power dissipation for nominal condition: ≤ 0.9 VA
- Fuse: Slow-blow
- General Rated voltage: 250 V AC
- Rated current I N: 5 A
- Rated surge voltage: 2.5 kV
- Insulation resistance R iso: > 100 MΩ (500 V DC)
- Tripping method: T (thermal)
- Device resistance: 0.05 Ω
- Rated short-circuit switching capacity I cn: 30 A (250 V AC / 65 V DC)
- Short-circuit switching capacity: 2000 A (250 V AC / UL 1077)
More info
▲| General | When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly. |
| Type | Male |
| Product type | Thermal device circuit breakers |
| Number of positions | 1 |
| Insulation characteristics | |
| Overvoltage category | II |
| Degree of pollution | 2 |
| Fuse type | Automatic device |
| Maximum power dissipation for nominal condition | ≤ 0.9 VA |
| Fuse | Slow-blow |
| General | |
| Rated voltage | 250 V AC |
| 65 V DC | |
| 250 V AC (AC according to UL 1077) | |
| 72 V DC (DC according to UL 1077) | |
| Rated current IN | 5 A |
| Rated surge voltage | 2.5 kV |
| Insulation resistance Riso | > 100 MΩ (500 V DC) |
| Tripping method | T (thermal) |
| Device resistance | 0.05 Ω |
| Rated short-circuit switching capacity Icn | 30 A (250 V AC / 65 V DC) |
| 50 A (30 V DC) | |
| Short-circuit switching capacity | 2000 A (250 V AC / UL 1077) |
| 2000 A (72 V DC / UL 1077) | |
| Dielectric strength | 3000 V AC (Actuation area) |
| 1500 V AC (Installation area) | |
| Switching cycles, max. | 6000 (At 1 x In, low-induction) |
| 3000 (At 1 x In, inductive) | |
| 500 (At 2 x In, inductive) | |
| Connection method | pluggable |
| Dimensional drawing | |
| Width | 8.2 mm |
| Height | 24.4 mm |
| Depth | 44.5 mm |
| Flammability rating according to UL 94 | V-0 |
| Insulating material group | IIIb |
| Insulating material | PPS |
| Mechanical data | |
| Open side panel | No |
| Ambient conditions | |
| Degree of protection | IP40 (Actuation area) |
| Ambient temperature (operation) | -20 °C ... 60 °C |
| Altitude | ≤ 4000 m (amsl) |
| Humidity test | 240 h, 95 % RH, 40 °C |
| Mounting type | on base element |