The Phoenix Contact TCP 10/12A single-channel thermal switch for equipment protection, to protect consum.. functions as a dedicated thermal switch designed to shield sensitive electronic loads and system components from thermal overload. Industrial setups rely on these devices to automatically interrupt circuits when excessive current draw threatens connected hardware integrity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type: Male
- Product type: Thermal device circuit breakers
- Number of positions: 1
- Insulation characteristics Overvoltage category: II
- Degree of pollution: 2
- Fuse type: Automatic device
- Fuse: Slow-blow
- General Rated voltage: 250 V AC
- Rated current I N: 12 A
- Rated surge voltage: 2.5 kV
- Insulation resistance R iso: > 100 MΩ (500 V DC)
- Tripping method: T (thermal)
- Device resistance: 0 Ω
- Rated short-circuit switching capacity I cn: 30 A (250 V AC)
- Short-circuit switching capacity: 2000 A (250 V AC / UL 1077)
- Dielectric strength: 3000 V AC (Actuation area)
More info
▲| Type | Male |
| Product type | Thermal device circuit breakers |
| Number of positions | 1 |
| Insulation characteristics | |
| Overvoltage category | II |
| III (Actuation area) | |
| Degree of pollution | 2 |
| Fuse type | Automatic device |
| Fuse | Slow-blow |
| General | |
| Rated voltage | 250 V AC |
| 72 V DC | |
| 250 V AC (UL/CSA) | |
| 72 V DC (UL/CSA) | |
| Rated current IN | 12 A |
| Rated surge voltage | 2.5 kV |
| Insulation resistance Riso | > 100 MΩ (500 V DC) |
| Tripping method | T (thermal) |
| Device resistance | 0 Ω |
| Rated short-circuit switching capacity Icn | 30 A (250 V AC) |
| 50 A (72 V DC) | |
| Short-circuit switching capacity | 2000 A (250 V AC / UL 1077) |
| 2000 A (72 V DC / UL 1077) | |
| Dielectric strength | 3000 V AC (Actuation area) |
| 1500 V AC (Installation area) | |
| Switching cycles, max. | 6000 (At 1 x In, low-induction) |
| 3000 (At 1 x In, inductive) | |
| 40 (at 6 x In, AC) | |
| Connection method | pluggable |
| Dimensional drawing | |
| Width | 9.5 mm |
| Height | 24.4 mm |
| Depth | 44.5 mm |
| Flammability rating according to UL 94 | V-0 |
| Insulating material group | IIIb |
| Insulating material | PPS |
| Mechanical data | |
| Open side panel | No |
| Ambient conditions | |
| Degree of protection | IP40 (Actuation area) |
| IP00 (Connection area) | |
| Ambient temperature (operation) | -20 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 4000 m (amsl) |
| Humidity test | 240 h, 95 % RH, 40 °C |
| Shock (operation) | 25g (11 ms period, half-sine shock pulse, according to IEC 60068-2-27) |
| Vibration (operation) | ± 0.38 mm (10 ... 57 Hz) |
| 5g (57 ... 500 Hz) | |
| Mounting type | on base element |