View larger
TC-2KS40-AI16-M-PRH-CS 2905257 PHOENIX CONTACT Module carrier
TC-2KS40-AI16-M-PRH-CS
2905257
PHOENIX CONTACT
1 Pcs.
Automation > Interface module
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed to support specialized controller architectures, the TC-2KS40-AI16-M-PRH-CS 2905257 PHOENIX CONTACT Module carrier establishes an organized platform for managing system I/O channels. Module carriers are widely utilized in large-scale industrial automation plants to mount, power, and safeguard signal conditioning hardware efficiently within control cabinets.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Module carrier
- Data management status Article revision: 06
- Overvoltage category: II
- Pollution degree: 2
- Max. permissible current: 23 mA (Signal/channel)
- Nominal voltage U N: < 30 V DC (Per signal/channel)
- Rated surge voltage: 0.5 kV
- Supported controller YOKOGAWA CENTUM VP Suitable I/O card: AAI143
- Supply Designation: Power module
- Fuse: 2x 2.5 A on PCB, slow-blow (replaceable)
- Input voltage: 24 V DC
- Input voltage range: 19.2 V DC ... 30 V DC
- Input current: ≤ 2 A
- Redundant supply: yes, decoupled from diodes
- Polarization and surge protection: Yes
- Output name: Switching output
More info
▲| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Product type | Module carrier |
| Data management status | |
| Article revision | 06 |
| Insulation characteristics: Air clearances and creepage distances | |
| Insulation | Basic insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
| Max. permissible current | 23 mA (Signal/channel) |
| Nominal voltage UN | < 30 V DC (Per signal/channel) |
| Air clearances and creepage distances | |
| Rated insulation voltage | 50 V |
| Rated surge voltage | 0.5 kV |
| Supported controller YOKOGAWA CENTUM VP | |
| Suitable I/O card | AAI143 |
| Supply | |
| Designation | Power module |
| Note | Power supply via 2902958 MINI MCR-SL-PTB-FM power terminal and 2902961 MINI MCR-SL-FM-RC-NC error signaling module. |
| Fuse | 2x 2.5 A on PCB, slow-blow (replaceable) |
| Input voltage | 24 V DC |
| Input voltage range | 19.2 V DC ... 30 V DC |
| Input current | ≤ 2 A |
| Redundant supply | yes, decoupled from diodes |
| Polarization and surge protection | Yes |
| Output name | Switching output |
| Contact switching type | 1 N/C contact (alarm = open) |
| Maximum switching voltage | 30 V DC (50 mA) |
| Power supply | |
| Connection method | Screw connection |
| Stripping length | 7 mm |
| Number of connections | 1 |
| Number of positions | 6 |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Controller level | |
| Connection method | Yokogawa KS-compatible |
| Number of connections | 2 |
| Number of positions | 40 |
| Status display | 2 x red LED (error) |
| 2x green LEDs (PWR1 and PWR2) |
| Width | 147 mm |
| Height | 170 mm |
| Depth | 159.5 mm |
| Flammability rating according to UL 94 | V0 |
| Ambient conditions | |
| Degree of protection | IP00 |
| Ambient temperature (operation) | -20 °C ... 60 °C (Please observe module specifications) |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Shock | 15g, according to IEC 60068-2-27 |
| Vibration (operation) | 2g, according to IEC 60068-2-6 |
| UL, USA/Canada | |
| Identification | UL 61010 Listed |
| Class I, Div. 2, Groups A, B, C, D T4 | |
| Class I, Zone 2, Group IIC | |
| Air clearances and creepage distances | |
| Standards/regulations | DIN EN 50178 |
| Mounting type | DIN rail mounting |
| Assembly note | No end clamp |
| Mounting position | vertical, horizontal |