The Phoenix Contact PT-IQ-1X2-TELE-PT is a surge protection device built to safeguard telecommunication systems against transient overvoltages and sudden voltage spikes. Such components are typically installed within industrial control panels and network infrastructures to protect sensitive electronics from lightning strikes and switching operations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Nominal voltage AC (EF008798): 180 V
More info
▲Key Commercial Data
| Orderkey | 2801290 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 163 (C-4-2017) |
| GTIN | 4046356766715 |
| Weight per Piece (excluding packing) | 108.900 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 70 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 4000 m (amsl (above mean sea level)) |
| Degree of protection | IP20 |
General
| Housing material | PA 6.6 |
|---|---|
| Flammability rating according to UL 94 | V-0 |
| Color | jet black RAL 9005 |
| Mounting type | DIN rail: 35 mm |
| Type | DIN rail module, two-section, divisible |
| Direction of action | Line-Line & Line-Earth Ground |
Protective circuit
| IEC test classification | C1 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| B2 | |
| VDE requirement class | C1 |
| C2 | |
| C3 | |
| D1 | |
| B2 | |
| Nominal voltage UN | 180 V DC |
| Maximum continuous voltage UC | 180 V DC |
| Rated current | 150 mA (25 °C) |
| Operating effective current ICat UC | ≤ 1 µA |
| Residual current IPE | ≤ 1 µA |
| Nominal discharge current In(8/20) µs (line-line) | 10 kA |
| Nominal discharge current In(8/20) µs (line-earth) | 10 kA |
| Pulse discharge current Iimp(10/350) µs (line-earth) | 2.5 kA |
| Total discharge current Itotal(8/20) µs | 20 kA |
| Voltage protection level Up(line-line) | ≤ 290 V (B2 - 100 A) |
| ≤ 290 V (C1 - 1 kV) | |
| ≤ 290 V (C2 - 10 kV) | |
| ≤ 300 V (C2 - 10 kA) | |
| ≤ 290 V (C3 - 50 A) | |
| Voltage protection level Up(line-earth) | ≤ 500 V (B2 - 100 A) |
| ≤ 600 V (C1 - 1 kV) | |
| ≤ 600 V (C2 - 10 kV) | |
| ≤ 650 V (C2 - 10 kA) | |
| ≤ 700 V (C3 - 50 A) | |
| Response time tA(line-line) | ≤ 1 ns |
| Response time tA(line-earth) | ≤ 100 ns |
| Input attenuation aE, sym. | typ. 0.3 dB (≤ 5 MHz / 150 Ω) |
| Cut-off frequency fg (3 dB), sym. in 150 Ohm system | typ. 25 MHz |
| Capacity (line-line) | typ. 60 pF |
| Resistance in series | 1.2 Ω ±5 % |
| Surge protection fault message | Optical, multi-stage |
| Max. required back-up fuse | 150 mA (slow-blow) |
| Impulse durability (line-line) | C1 - 500 A |
| C2 - 10 kA | |
| C3 - 50 A | |
| B2 - 100 A | |
| Impulse durability (line-earth) | C1 - 500 A |
| C2 - 10 kA | |
| C3 - 50 A | |
| B2 - 100 A | |
| D1 - 2.5 kA | |
| Pulse reset time (line-line) | ≤ 30 ms |
Connection data
| Connection method | Push-in connection |
|---|---|
| Stripping length | 10 mm |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section solid | 0.2 mm² ... 4 mm² |
| Conductor cross section AWG | 24 ... 12 |
Standards and Regulations
| Standards/specifications | IEC 61643-21 2000 + A1:2008 + A2:2012 |
|---|---|
| EN 61643-21 2001 + A1:2009 + A2:2013 | |
| EN 61000-6-2 2005 | |
| EN 61000-6-3 2007 + A1:2011 |